IO. Alternator
@ Measure
voltage
at V2 (voltage
across
terminals
F and E) while
gradually
increasing
the resistance
of the variable resistor starting from
0 V.
Check that there is a point
where the V2 voltage reaches 2.0 V
or less of the Vl value
of BAT1
measured
in @ above.
If no
change
occurs,
the regulator
is
faulty.
So, replace
it with a new
one.
@ Measure
voltage
at V4 (voltage
across the intermediate
tap of the
variable
resistor
and E-terminal),
with
variable
resistor
Rv being
fixed.
If the measured
value
is
within
the specified
range,
the
regulator
is acceptable.
If not, the
regulator
is faulty.
So, replace
it
with a new one.