Upper Boom Control Switch

The upper boom switch initiates or turns off flow from the upper boom.

Lower Boom Control Switch

The lower boom switch initiates or turns off flow from the lower boom.

Water Application Rate Scaling Switch

This switch allows the operator to increase or decrease the water flow rate from as low as 50%
of its pre-calibrated value to as high as 150% of its pre-calibrated value.
-
The factory-set system flow rates are 10.5 GPM from the Upper Boom and 3.8 GPM
from the Lower Boom at a 5 MPH reference speed. The total flow from both
booms for these flow rates is 14.3 GPM.

Blast Button

This function allows the operator to apply the maximum water flow rate set in the control
system for up to 10 seconds at a time.
-
The factory setting for the maximum water flow rate is 25.7 GPM.