Quadruple mode

5-3-2. High-speed counter range

The counting range of high-speed counter is: -2147483648 ~ +2147483647. When the count value exceeds this
range, overflow or underflow occurs.
The overflow means that the count value jumps from +2147483647 to -2147483648 and continues counting.
When underflow occurs, the count value jumps from -2147483648 to +2147483647 and continues counting.

5-3-3. High-speed counter input wiring

For the counting pulse input terminal wiring, it is slightly different according to the programmable controller
type and counter model. Several typical input terminal wiring methods are shown in the following figure:
(1) Incremental mode
L+
X0+
M
X0-

5-3-4. Input terminal assignment

(1) XSDH/XS3/XSLH series PLC high speed counter channels:
PLC model
XSDH
60 points
XS3
26 points
XSLH
30 points
(Counter 0)
Pulse input
X1+
X2
X3-
X1-
X3+
X4
Incremental mode
(2) AB phase mode
L+
X0+
M
X0-
High speed counter channel
4
4
4
38
X1+
X2
X3-
X1-
X3+
X4
AB phase mode
4
4
4