2. Programming Commands

132: Send Tampers as Burglary

Some Alarm Receiving Centres (ARCs) experience problems if a control unit
sends "restore" messages using SIA, wrongly interpreting them as "user
restores". When using SIA reporting, Command 132 enables you to program
the control unit to send tampers as alarms.
Option
0
The control unit sends all SIA messages as specified in Command
131 (default).
1
For full alarm response, the control unit sends tampers as burglary
(BA) and sends Contact ID 130 in place of Contact ID 137.
Notes:
1.
Compliance with PD 6662 / prEN 50131-1: 2004 (see page 86) at Grade 3 requires
that Command 132 is set to 0.
2.
Fast Format and plug-by outputs send tampers as alarms only if no tampers are
allocated using Commands 151-158, 191-198, 211-218. As the default settings do
not include tamper allocations, the normal operation of these outputs is to send
tampers as alarms.

133: Do not Send SIA Restores

Use this command to stop the system sending SIA restore messages.
Option
0
SIA Restores Off (default). System does not send SIA restore
messages: FR (Fire Restore), PR (Panic Restore), UR (Technical
Restore), BR (Burglary Restore) or TR (Tamper Restore).
1
SIA Restores On. System sends SIA restore messages.

134: AC Fail User/Installer Reset

Use this command to determine how AC Fail alerts are reset.
Option
0
No Reset Required (default). An alert is generated when the mains
power supply fails and reset automatically when the supply is
restored.
1
User Reset. An alert is generated when the mains power supply fails
and can be reset by the user or installer when the supply is restored.
2
Installer Reset. An alert is generated when the mains power supply
fails and can be cleared only by the installer when the supply is
restored.
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 86) requires that
Command 134 is set to 1 or 2 (Cooper Security recommends 1).