95 Installation Instructions
Output Module Connector
("20" in Figure 2.)
CPA6 output modules can be connected to the OUTPUT MODULE connector
to provide eight additional 100mA switched-negative programmable outputs
per module. The outputs can be used to drive LEDs or other low-power
devices (see Figure 17).
Each output module is supplied with an interface lead, which enables easy
connection to the control panel (or to an MSNode).
When the output module is connected to the control panel, the outputs can be
programmed to indicate partition status or zone alarms.
For further details, please refer to the CPA6 Output Module Installation
Instructions.
Connect to plug
labelled OUTPUT
MODULE
Engineer Keypad Connector
("21" in Figure 2.)
A keypad set with its ID selector switch set "ENG" can be connected directly
to the ENGINEERS KEYPAD connector on the control panel, using the
Engineer Keypad Interface (EKI) lead. (Figure 18 provides connection
details.)
An engineer's keypad is intended to be temporary connected to the control
panel for system configuration and testing at the control panel. The keypad
can be disconnected without causing an alarm. Once a system has been set
up, system configuration should normally be carried out from a keypad
attached to Network 1 or 2.
The zone and output terminals on an engineer's keypad cannot be used.
100m max.
PL1
Figure 17. Output Module Connections
11680293 Issue 1
PL2
1 2 3 4
5 6 7 8
1k Resistors
LEDs
2. Installation
Page 19