CLEARANCES CLEARANCES TO COMBUSTIBLES ALCOVE CLEARANCES These dimensions are minimum clearances to combustibles, however it is highly recommended that you leave sufficient room on each side (20" where possible) for servicing, routine cleaning and maintenance. Minimum Width 36" (914mm) This pellet stove requires floor protection. The floor protection must be non-combustible, extending 6"...
VENT TERMINATION REQUIREMENTS Minimum Clearance Letter Description 24 in (61cm) Above grass, top of plants, wood, or any other combustible materials. 48 in (122cm) From beside/below any door or window that may be opened. (18" [46cm] if outside fresh air installed). 12 in (30cm) From above any door or window that may be opened.
EXHAUST AND FRESH AIR INTAKE LOCATION Outside Fresh Air Connection: Outside fresh air is mandatory when installing this unit in EXHAUST: airtight homes and mobile homes. Base of unit to center of flue 20-5/16" (508mm) A Fresh-air intake is strongly recommended for all installations. Failure to install intake air may result in improper combustion as well Side of unit to center of flue 6-11/16"...
HORIZONTAL EXHAUST THROUGH WALL INSTALLATION Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor, or ceiling. Where passage through Exhaust Tube a wall or partition of combustible construction is desired, the installation 3"...
VERTICAL RISE WITH HORIZONTAL INSIDE VERTICAL INSTALLATIONS TERMINATION INSTALLATION 1. Choose a stove location that is ideal. Refer to "Locating Your Pellet A 45° elbow may be used in place of the termination cap (or stainless Appliance" section. steel termination hood). 2.
Steel Plate or Flashing Flexible or Rigid 6" Stainless Steel Liner HEARTH MOUNT INSTALLATION Refer to Figures on the left: Damper Removed 1. Install the hearth pad. or Fastened Open 2. Lock the fireplace damper in the open position. 10" (25.4 cm) Mantel 3.
Page 8
TOP VENT ADAPTOR KIT & 3” (76 MM) TO 6” (152 MM) FLUE ADAPTOR (APPROVED TOP VENT ADAPTOR KIT & 3” (76 MM) TO 6” (152 MM) FLUE ADAPTOR (APPROVED FOR FOR VERTICAL INSTALLATIONS ONLY) VERTICAL INSTALLATIONS ONLY) 3PVP-X6 3” (76mm) pipe lengths to class A chimney GF55-920 *In order to achieve the maximum rated efficiency of 75% HHV purchase of a top vent adaptor kit (GF55-920) is required.