Cable Size And Crimping Terminal; Specifications - Mitsubishi FR-HEL Series Instruction Manual

Hide thumbs Also See for FR-HEL Series:
Table of Contents

Advertisement

Cable Size and Crimping Terminal

4
Cable Size and Crimping Terminal
(1) 200V class
Type
FR-HEL-0.4K to 2.2K
FR-HEL-3.7K
FR-HEL-5.5K
FR-HEL-7.5K
FR-HEL-11K
FR-HEL-15K
FR-HEL-18.5K
FR-HEL-22K
FR-HEL-30K
FR-HEL-37K
FR-HEL-45K,55K
(2) 400V class
Type
FR-HEL-H0.4K to H2.2K
FR-HEL-H3.7K
FR-HEL-H5.5K,H7.5K
FR-HEL-H11K
FR-HEL-H15K
FR-HEL-H18.5K
FR-HEL-H22K,H30K
FR-HEL-H37K
FR-HEL-H45K
FR-HEL-H55K
5

Specifications

Power Factor Improving Effect * Power supply power factor 93% or more (at 100% load)
Power specifications
Ambient temperature
Ambient humidity
Envi-
Storage temperature
ron-
ment
Atmosphere
Altitude/vibration
*The power factor is calculated on the assumption that the power impedance is 1%. The value
changes according to the power supply capacity and power impedance. The load is calculated
using the fundamental current specified in JEM-TR201 as 100%.
For a motor of less than 0.4kW, the power factor improving effect will be slightly lower.
4
Terminal
Crimping Terminal
Screw Size
M4
M4
M4
M5
M6
M6
M8
M10
38-10
M10
60-10
M10
80-10
M12
100-12
Terminal
Crimping Terminal
Screw Size
M3.5
M4
M4
M5
M6
M6
M6
M8
M8
M8
Three-phase AC 200 to 240V 50Hz/60Hz 380 to 480V 50Hz/
60Hz
-10°C to + 50°C (non-freezing)
90%RH or less (non-condensing)
-20°C to + 65°C (non-freezing)
Indoors (free from corrosive gas, flammable gas, oil mist, dust
and dirt)
Max.1000m above sea level 5.9m/s
HIV Cable Size (mm
2-4
5.5-4
5.5-4
14-5
14-6
22-6
38-8
HIV Cable Size (mm
2-3.5
2-4
5.5-4
5.5-5
8-6
14-6
22-6
22-8
38-8
60-8
2
or less
2
)
2
3.5
5.5
14
14
22
38
38
60
80
100
2
)
2
2
3.5
5.5
8
14
22
22
38
60

Advertisement

Table of Contents
loading

Table of Contents