Display Setup; Trigger Setup; Zone 2/Ms Out - NAD M15 Owner's Manual

Av surround sound preamplifier
Hide thumbs Also See for M15:
Table of Contents

Advertisement

M15 02 23 2006.qxd
3/7/2006
Setup
USING THE M15

DISPLAY SETUP

->
TV SYSTEM
->
MONITOR TYPE
->
SUPERIMPOSE
->
TEMP DISPLAY
DISPLAY SETUP
->
TV SYSTEM
->
MONITOR TYPE
->
SUPERIMPOSE
->
TEMP DISPLAY

TRIGGER SETUP

->
TRIGGER
->
ASSIGNED TO
->
POLARITY
->
DELAY (S)
->
DURATION (S)
->
TRIGGER INPUT ON
->
->TRIGGER
TRIGGER SETUP
->
TRIGGER
->
ASSIGNED TO
->
POLARITY
->
DELAY (S)
->
DURATION (S)
->
INPUT
->
VOLUME
->
VOL DEFAULT
->
INPUT
->
VOLUME
->
VOL DEFAULT
32
9:06 AM
Page 32
DISPLAY SETUP
TV SYSTEM
Select between NTSC and PAL systems. Select NTSC (North American) or PAL (European) TV System in
NTSC
YUV
order to view the OSD on your monitor. This setting only affects the OSD, the source material will be
ON
displayed in its native format.
FULL
MONITOR TYPE
This setting sets the
inputs using both S-Video and CVBS, only YUV is available.
SUPERIMPOSE
You may superimpose the Setup OSD over any existing video by selecting ON. The OFF setting places the
OSD over a black background.
TEMP DISPLAY (TEMPORARY OSD)
One may display the operating state of the M15 temporarily by setting this variable to FULL. Otherwise
PAL
YUV
when the variable is set to SIMPLE only the volume OSD will display. A setting of OFF will disable the
temporary OSD.
ON
SIMPLE
Note: To display a temporary OSD on the MS OUT COMPOSITE VIDEO, the TEMP DISPLAY may be
set to either SIMPLE or FULL.
TRIGGER SETUP
TRIGGER 1 & TRIGGER 2+3
1
There are two trigger assignments, Trigger 1 and Trigger 2+3. The trigger outputs can be assigned to;
POWER ON
HIGH
POWER ON, ZONE 2, DVD, SAT, VCR, Video 4, Video 5, Video 6, Disc, CD, and Tuner.
0
INFINITE
POLARITY
One may assign the steady-state of the trigger polarity to either POLARITY variables HIGH or LOW. This
2+3
steady-state polarity is the 'active' final state of the trigger output signal.
2+3
DELAY (S)
ZONE 2
HIGH
The delay between when one selects the assignment either from the front panel or HTRM remote, to
1
when the trigger signal will transition. The values are in seconds, set from 0, 1, or 5 seconds.
INFINITE
DURATION (S)
The duration of the steady state may be set in seconds from 1, 5, 10, 30, to INFINITE.
TRIGGER INPUT
when the TRIGGER INPUT is set to ON, the M15 will turn on from the standby state when a DC +12V
signal is present at the TRIGGER IN socket. As long as the signal is present the M15 will remain in the
ON state. When the +12V signal is absent, the M15 will revert to its standby state.
Note: The front panel button or the HTRM remote control can override the TRIGGER IN signal

ZONE 2/MS OUT

ZONE 2
INPUT
Using the HTRM remote, select an input to display on the ZONE 2/MS OUT via this OSD menu. All inputs
SAT
other than tape monitor and ext. 7.1 can be selected at the ZONE 2/MS OUT using your HTRM remote
-20.0dB
control in the main zone.
-20.0dB
VOLUME
This volume setting is the temporary volume setting of the ZONE 2/MS OUT via HTRM remote control.
ZONE 2
Adjust the level using the HTRM's navigation arrows
SAT
VOL DEFAULT (START UP ZONE 2 VOLUME)
-12.0dB
This volume setting is the default volume setting from standby. The level may be set from mute to +12
-20.0dB
dB using the same navigation arrows above. To store the value one must press the HTRM's ENTER button.
MONITOR OUT
of the M15. Select between YUV, S-Video and CVBS. For source
or
from mute to +12 dB.