Chapter 4
[UA-90]~[UA-94][Ub-01]~
[Ub-05][UC-01]
Unit selection
Code/Name
UA-90
QOP indication off waiting
time
UA-91
Initial display selection
UA-92
auto return to initial display
enable
UA-93
Setting enable at monitor
display
UA-94
Multispeed change on the
frequency reference monitor
display
・Setting parameter for MOP(VR)keypad. Refer to
MOP(VR)instruction for more detail.
Initialize
Code/Name
00(Disable)/
01(Error history clear)/
02(Initialize parameter)/
03(Error history clear +
initialize parameter)/
04(Error history clear +
initialize Parameter + EzSQ
Ub-01
clear)/
Initialize
05(Except terminal
mode selection
configuration)/
06(Except communication
configuration)
07(Except terminal &
communication
configuration)
08(EzSQ only)
00(pattern 0)/
Ub-02
01(pattern 1)/
Initialize
02(pattern 2)/
data selection
03(pattern 3)
Ub-03
00(VLD)/01(LD)/02(ND)
Load type selection
Ub-05
00(Disable)/
Initialize
01(Execute initialization)
enable
・To initialize; after setting [Ub-01], setting [Ub-05]=01 will
start the initialize process.
・Once setting the load type selection [Ub-03],will change
instantaneously the inverter load rating.
Factory settings
Code/Name
UC-01
(-)
Initial
Range (unit)
value
0~60(min)
(Select
from
d,
f
dA-01
parameters)
00(Disable)/
00
01(Enable)
00(Disable)/
00
01(Enable)
00(Disable)/
00
01(Enable)
Initial
Range (unit)
value
00
00(JPN)
01(EU)
02(USA)
03(CHN)
02
00
Range (unit)
Initial value
(Do not change)
(00)
For parameter configuration
Trace function
Code/Name
Ud-01
Trace function enable
Ud-02
Trace start
0
Ud-03
Trace data number
selection
Ud-04
Trace signal number setting
Ud-10
Trace data 0 selection
Ud-11
Trace data 1 selection
Ud-12
Trace data 2 selection
Ud-13
Trace data 3 selection
Ud-14
Trace data 4 selection
Ud-15
Trace data 5 selection
Ud-16
Trace data 6 selection
Ud-17
Trace data 7 selection
Ud-20
Trace signal 0 Input/Output
selection
Ud-21
Trace signal 0 input
terminal selection
Ud-22
Trace signal 0 output
terminal selection
Ud-23
Trace signal 1 Input/Output
selection
Ud-24
Trace signal 1 input terminal
selection
Ud-25
Trace signal 1 output
terminal selection
Ud-26
Trace signal 2 Input/Output
selection
Ud-27
Trace signal 2 input terminal
selection
Ud-28
Trace signal 2 output
terminal selection
Ud-29
Trace signal 3 Input/Output
selection
Ud-30
Trace signal 3 input terminal
selection
Ud-31
Trace signal 3 output
terminal selection
Ud-32
Trace signal 4 Input/Output
selection
Ud-33
Trace signal 4 input terminal
selection
Ud-34
Trace signal 4 output
terminal selection
Ud-35
Trace signal 5 Input/Output
selection
Ud-36
Trace signal 5 input terminal
selection
Ud-37
Trace signal 5 output
terminal selection
・Trace function settings.
For more information, refer to the user's guide.
4-56
[Ud-01]~[Ud-37]
Initial
Range (unit)
value
00(Disable)/
00
01(Enable)
00(Stop)/
00
01(Start)
1
1~8
1~8
1
dA-01
dA-01
dA-01
dA-01
(Select from d, f
parameters)
dA-01
dA-01
dA-01
dA-01
00(Input:[Ud-21]))/
00
01(Output:[Ud-22])
Same as [CA-01]
001
Same as [CC-01]
001
00(Input:[Ud-24]))/
00
01(Output:[Ud-25])
Same as [CA-01]
001
Same as [CC-01]
001
00(Input:[Ud-27]))/
00
01(Output:[Ud-28])
Same as [CA-01]
001
Same as [CC-01]
001
00(Input:[Ud-30]))/
00
01(Output:[Ud-31])
Same as [CA-01]
001
Same as [CC-01]
001
00(Input:[Ud-33]))/
00
01(Output:[Ud-34])
Same as [CA-01]
001
Same as [CC-01]
001
00(Input:[Ud-36]))/
00
01(Output:[Ud-37])
Same as [CA-01]
001
Same as [CC-01]
001