Chapter 4
[Ab-01]~[Ab-25]
Scaled Output Frequency gain monitor [dA-06]
Code/Name
Ab-01
Frequency
conversion gain
・The visualized "Scaled Output frequency [dA-06]" is
equal to the "Output frequency [dA-01]" multiplied by the
"Frequency scaling conversion factor[Ab-01]".
Multispeed command
Code/Name
Ab-03
Multispeed operation
selection
Ab110
Multispeed-0, 1st-motor
Ab-11
Multispeed-1, 1st-motor
Ab-12
Multispeed-2, 1st-motor
Ab-13
Multispeed-3, 1st-motor
Ab-14
Multispeed-4, 1st-motor
Ab-15
Multispeed-5, 1st-motor
Ab-16
Multispeed-6, 1st-motor
Ab-17
Multispeed-7, 1st-motor
Ab-18
Multispeed-8, 1st-motor
Ab-19
Multispeed-9, 1st-motor
Ab-20
Multispeed-10, 1st-motor
Ab-21
Multispeed-11, 1st-motor
Ab-22
Multispeed-12, 1st-motor
Ab-23
Multispeed-13, 1st-motor
Ab-24
Multispeed-14, 1st-motor
Ab-25
Multispeed-15, 1st-motor
・For the 16 speeds selection, set [Ab-03]=03 for
assigning the intelligent terminals 003[CF1] to
006[CF4] makes available the use of the speeds 0 to
15.
Multispeed
CF4
CF3
Speed 0
OFF
OFF
Speed 1
OFF
OFF
Speed 2
OFF
OFF
Speed 3
OFF
OFF
Speed 4
OFF
ON
Speed 5
OFF
ON
Speed 6
OFF
ON
Speed 7
OFF
ON
Speed 8
ON
OFF
Speed 9
ON
OFF
Speed 10
ON
OFF
Speed 11
ON
OFF
Speed 12
ON
ON
Speed 13
ON
ON
Speed 14
ON
ON
Speed 15
ON
ON
Range (unit)
Initial value
0.00~100.00
1.00
Range (unit)
Initial
value
00(16 speeds)/
00
01(8 speeds)
0.00~590.00(Hz)
0.00
0.00
0.00~590.00(Hz)
0.00~590.00(Hz)
0.00
0.00
0.00~590.00(Hz)
0.00~590.00(Hz)
0.00
0.00~590.00(Hz)
0.00
0.00~590.00(Hz)
0.00
0.00~590.00(Hz)
0.00
0.00
0.00~590.00(Hz)
0.00~590.00(Hz)
0.00
0.00
0.00~590.00(Hz)
0.00~590.00(Hz)
0.00
0.00~590.00(Hz)
0.00
0.00~590.00(Hz)
0.00
0.00~590.00(Hz)
0.00
0.00
0.00~590.00(Hz)
CF2
CF1
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
For parameter configuration
[Ab210][AC-01]~[AC-02]
・For the 8 speeds selection, set [Ab-03]=01 assigning the
intelligent terminals 007[SF1] to 013[SF7] makes
available the use of the speeds 0 to 7.
Multispeed
SF7
SF6
Speed 0
OFF
OFF
Speed 1
-
-
Speed 2
-
-
Speed 3
-
-
Speed 4
-
-
Speed 5
-
-
Speed 6
-
ON
Speed 7
ON
OFF
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Code/Name
Ab210 Multispeed-0, 2nd-motor
Input method for Acc/Decel time
Code/Name
AC-01
Acceleration/Deceleration
Time input selection
・[AC-01] changes the reference target for the Acc/Decel
command.
Individual Acc/Decel for Multispeed
Code/Name
AC-02
Acceleration/
Deceleration selection
・When [AC-02]=00, the acceleration/deceleration time
settings [AC120][AC122] or [AC124][AC126] will be in
effect.
・2-stage acceleration/deceleration functions from
[AC115] to [AC117] can be set.
・When [AC-02]=01, the acceleration/deceleration time
[AC-30]~[AC-88] for each multispeed control (from
speed 1 to 15) are enabled.
・When [AC-02]=01, while in Multspeed-0 command,
Acc/Decel setting [AC120] [AC122] or Acc/Decel setting
[AC124] [AC126] are enabled.
・During remote control up/down [FUP]/[FDN]
(parameters [CA-64] and [CA-66]) and PID soft start
(parameter [AH-78]), those parameters can be
overwritten.
4-11
SF5
SF4
SF3
SF2
OFF
OFF
OFF
OFF
-
-
-
-
-
-
-
ON
-
-
ON
OFF
-
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Range (unit)
Same as Ab110
Range (unit)
00(Parameter)/
01(Option 1)/
02(Option 2)/
03(Option 3)/
04(Function EzSQ)
Range (unit)
Initial value
00(Common)/01(Multi)
SF1
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
Initial
value
Initial
value
00
00