Chapter 4
[db-01]~[db-64]
Code/Name
db-01
Program download monitor
db-02
Program No. monitor
db-03
Program counter (Task-1)
db-04
Program counter (Task-2)
db-05
Program counter (Task-3)
db-06
Program counter (Task-4)
db-07
Program counter (Task-5)
db-08
User monitor -0
db-10
User monitor -1
db-12
User monitor -2
db-14
User monitor -3
db-16
User monitor -4
db-18
Analog output monitor YA0
db-19
Analog output monitor YA1
db-20
Analog output monitor YA2
db-21
Analog output monitor YA3
db-22
Analog output monitor YA4
db-23
Analog output monitor YA5
Code/Name
db-30
PID1 feedback value 1 monitor
db-32
PID1 feedback value 2 monitor
db-34
PID1 feedback value 3 monitor
db-36
PID2 feedback value monitor
db-38
PID3 feedback value monitor
db-40
PID4 feedback value monitor
db-42
PID1 target value monitor
db-44
PID1 feedback value monitor
db-50
PID1 output monitor
db-51
PID1 deviation monitor
db-52
PID1 deviation 1 monitor
db-53
PID1 deviation 2 monitor
db-54
PID1 deviation 3 monitor
db-55
PID2 Output monitor
db-56
PID2 deviation monitor
db-57
PID3 Output monitor
db-58
PID3 deviation monitor
db-59
PID4 Output monitor
db-60
PID4 deviation monitor
db-61
Current PID P-Gain monitor
db-62
Current PID I-Gain monitor
db-63
Current PID D-Gain monitor
db-64
PID feedforward monitor
[dC-01]~[dC-50]
Range (unit)
00(Program is not
installed)/
01(Program is
installed)
0000~9999
0~1024
-2147483647
~+2147483647
0~10000
Range (unit)
0.00~100.00(%)
0.00~100.00(%)
0.00~100.00(%)
-100.00~+100.00(%)
-100.00~+100.00(%)
-100.00~+100.00(%)
-100.00~+100.00(%)
-100.00~+100.00(%)
-100.00~+100.00(%)
-100.00~+100.00(%)
-100.00~+100.00(%)
0.0~100.0
*1) Refer to users guide for detail
*2) The parameter is about Safety function,is not suitable for SH1 series.
0.0~3600.0(s)
0.0~100.0(s)
0.00~100.00(%)
4-7
For parameter configuration
Code/Name
dC-01
Inverter load type status
dC-02
Rated current monitor
dC-07
Main speed input source monitor
dC-08
Sub speed input source monitor
dC-10
RUN command input source monitor
dC-15
Cooling fin temperature monitor
dC-16
Life assessment monitor
dC-20
Accumulation Start number monitor
dC-21
Accumulation Power-on timer monitor
dC-22
Accumulated time monitor in RUN status
monitor
dC-24
Accumulation Power-on time monitor
dC-26
Accumulation cooling-fan running time
monitor
dC-37
icon 2 LIM monitor
dC-38
icon 2 ALT monitor
dC-39
icon 2 RETRY detail monitor
dC-40
icon 2 NRDY detail monitor
dC-45
IM/SM monitor
dC-50
Firmware ver. Monitor
Range (unit)
00(Very Low duty)/
01(Low duty)/
02(Normal duty)
*1)
*1)
*1)
*1)
-20.0~200.0(°C)
LL~HH
[L:Normal/H:Fatigued]
[Left](FAN lifespan)
(board capacitor life
span)[Right]
1~65535(cycles)
1~1000000(hour)
00(The state other than
the following)/
01(Overcurrent
restriction mode)/
02(Overload restriction)/
03(Overvoltage
restriction)/
04(Torque limit)/
05(上下限限制、跳频设
定限制中)/
06(Minimum frequency
setting restriction)
00(The state other than
the following)/
01(Overloading early
warning)/
02(Motor electric thermal
early warning)/
03(controller electric
thermal warning)/
04(Motor
overheating
early warning)
00(The state other than
the following)
01(waiting to retrying)
02(waiting to restart)
00 (Get ready ,The state
other than the following
IRDY=OFF)/
01 (Tripping)/
02 (Power anomaly)/03
(Resetting)/
04 (STO)*2) /05 (Standing
by)/
06 (Parameter
inconsistency
Other(without FB, AB
phase conflict ,etc.))/
07 (Sequence anomaly)/
08
(Free
running)/09
(Forcibly stop)
00 (IM selected)/
01 (SM selected)
00.000~99.99