MANUAL PN 123360 20221213MMF
SERVICING THE MACHINE
ERROR MESSAGES
Any errors that do not automatically clear themselves may be reset by turning power off
then back on using switch on the rear of unit.
ERROR 1/2/3
Program 1/2/3 has a bad value or cannot be read- this will reset the settings to default
values in programming.
Default volumes are 220 oz, 320 oz, and 270 oz for b1, b2, and b3, respectively.
Default times match ideal times in the table on page 10.
ERROR 5
Parameters either read out wrong, or were corrupted on startup. Restart machine. If this
error appears again, replace control board (PN 123336).
WIRING DIAGRAM
11