Download Print this page

Majestic Oslo Installation Manual page 4

Freestanding panel

Advertisement

The floor profile is supplied over-length; mark it to the width of the
1
glass with a strip of masking tape. Cut it to length, then file smooth.
Support Arm Boss Allen Bolt
Disassemble the support arms.
3
When measuring the arms the length is represented by X
( X ) mm
Grub Screw
Xmm
Floor or Tray
The Majestic Shower Company Limited
17 Flitch Industrial Estate, Chelmsford Road,
Dunmow, CM6 1XJ
Place the profile on the floor or tray, and mark its position using
masking tape.
2
Run a 3mm bead of silicone along the underside of the floor
profile, and carefully replace into the marked position; secure it
with masking tape.
Check that the supporting wall is square; make a note if it is
4
leaning by more than + or – 10mm at the approximate height
of the glass. Measure from the inside of the floor profile to the
supporting wall (Xmm), and minus 20mm from the figure; then
cut the support arm to the calculated length.
A: If the wall leans in at the top by more than 10mm, cut that
amount extra off the support arm.
B: if the wall leans out at the top by more than 10mm, leave
the amount extra on the length of the arm.
Telephone + 44 (0) 8448 001 500
Facsimile + 44 (0) 1279 635 074
info@majesticshowers.com www.majesticshowers.com

Advertisement

loading