Strip one end of each CES wire and attach a male blade connector to one end of each
wire (not necessary if soldering the connections). Connect the wires to the Posi-Taps
and run the free ends to the CES module, keeping clear of moving or heat-generating
devices. Excess wire can be trimmed but please keep in mind that the module may
have to be accessed to adjust the shutdown temperature or be removed to adjust
alarm volume, so, we suggest leaving enough slack to perform these functions.
Strip each end of the wires and connect to the appropriate terminals on the 5-terminal
connector as per the charts and diagrams.
Tighten each terminal by turning the
terminal screws clockwise until the wire is secure. Plug the 5-terminal connector into
the CES module and leave the module in a location where it can be accessed for
adjustments before final mounting.
NOTE: The 12v-power wire for the X Monitor module must be connected to the same
line as the "Keep Alive" is connected (See applicable chart for your application on
pages 8-12). Connect the power lead for the X Monitor module to the same "Keep
Alive" terminal on the CES module.
BD Engine Brake Inc.
Plant Address: Unit A10, 33733 King Rd, Abbotsford, BC, Canada V2S 7M9
U.S. Shipping Address: 88-446 Harrison St, Sumas, WA 98295
U.S. Mailing Address: P.O. Box 231, Sumas, WA 98295
Phone: 604-853-6096 Fax: 604-853-8749 Internet: www.bd-power.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

1081100

Table of Contents