Compatibility

If the X Monitor displays the two (2) readouts "PYRO" and "TURBO" only and is version
1.xx or 2.xx, the module and display will have to be updated so the CES will be
compatible. Call 1-800-887-5030 and ask for the claims division to arrange for this
update. All other units that display three (3) measurements do not need upgrading.

Notes on Connectors

The kit includes a number of Posi-Tap™ connectors (Gray/Black/Green) to tap onto
OEM wiring. It is important to select the correct color of connector so that it matches
the gauge of the OEM wire that it is being installed on. Using the incorrect connector
could cause an inadequate connection and/or the OEM wire could be severed.
Though these connectors offer a quicker installation, the best option would be to solder
the wires and isolate the joints with heat shrink or liquid electrical tape.
soldering techniques should be used to ensure adequate connections.
Insert Hot Wire
Make sure to center the wire when tightening the pierced portion of the hot wire to make a solid connection.

What is the COOL ENGINE SHUTDOWN (CES)?

The CES is designed to keep the engine running when the ignition key is turned off
and the exhaust temperature is above a set point (between 250-550°F) to prevent
turbocharger bearing failure that could occur when the engine is shutdown too quickly.
A typical turbocharger can spin in excess of 100,000rpm under load, which will
continue spinning when the engine is turned off.
The turbocharger is lubricated and cooled by engine oil - when the engine is turned off,
that oil supply is cut off. If a turbocharger is still spinning at a high RPM when the oil
supply is cut off, the internal bearings will utilize what remaining oil is left around them
U.S. Shipping Address: 88-446 Harrison St, Sumas, WA 98295
1081100 Cool Engine Shutdown
OEM Wire
18-22ga
12-18ga
10-12ga
Posi-Tap™ Connector Usage Diagram
Tighten
BD Engine Brake Inc.
Plant Address: Unit A10, 33733 King Rd, Abbotsford, BC, Canada V2S 7M9
Phone: 604-853-6096 Fax: 604-853-8749 Internet: www.bd-power.com
Posi-Tap™ Color
Gray or Red
Black
Green or Yellow
Strip Leads