schmersal SRB 324ST V.3 Operating Instructions Manual

schmersal SRB 324ST V.3 Operating Instructions Manual

Safety-monitoring module

Advertisement

Quick Links

Operating instructions
Safety-monitoring module
Operating instructions. . . . . . . . . . . . .pages 1 to 8
EN
Original
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2 Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.3 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.4 Setting report SRB 324ST V.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.2 Start configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8.4 Actuator configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9
EU Declaration of conformity
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module. The
operating instructions must be available in a legible condition and a
complete version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional
information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
SRB 324ST V.3
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB 324ST V.3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SRB 324ST V.3

  • Page 1: Table Of Contents

    Internet: 5.4 Setting report SRB 324ST V.3 ......5 www.schmersal.net.
  • Page 2: Warning About Misuse

    Operating instructions Safety-monitoring module SRB 324ST V.3 1.6 Warning about misuse The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant In case of inadequate or improper use or manipulations of standards.
  • Page 3: Classification

    Operating instructions Safety-monitoring module SRB 324ST V.3 Switching capacity of the safety contacts: The PFH values of 2.0 x 10 /h and 2.0 × 10 /h applies to the - 13-14, 23-24, 33-34 (STOP 0): max. 250 V, 8 A ohmic (inductive in...
  • Page 4: Description Of The Terminals

    Operating instructions Safety-monitoring module SRB 324ST V.3 DIP switch settings: 5.2 Description of the terminals • The DIP switches are located underneath the front cover of (see Fig. 1) the safety-monitoring module (see Fig. 3 and 4). Voltages: +24 VDC / 24 VAC •...
  • Page 5: Notes

    Fig. 6 Fig. 7 8.1 Wiring examples 5.4 Setting report SRB 324ST V.3 Dual-channel control, shownfora guard door monitor; with two This report regarding the setting of the device must be completed contacts A and B, where at least one is a positive break contact;...
  • Page 6: Start Configuration

    Operating instructions Safety-monitoring module SRB 324ST V.3 8.2 Start configuration +24V +24V External reset button (with edge detection) (see Fig. 9) • The external reset button is integrated as shown. • The safety-monitoring module is activated by the reset (after release) of the reset button (= detection of the trailing edge).
  • Page 7: Actuator Configuration

    Fig. 17 Fig. 18 Fig. 19 The connection of magnetic safety switches to the SRB 324ST V.3 safety-monitoring module is only admitted when the requirements of the standard IEC 60947-5-3 are observed. As the technical data are regarded, the following minimum requirements must be met: –...
  • Page 8 Safety-monitoring module SRB 324ST V.3 9. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.

Table of Contents