schmersal Elan SRB 201ZH X3 Operating Instructions Manual

schmersal Elan SRB 201ZH X3 Operating Instructions Manual

Safety-monitoring module

Advertisement

Quick Links

Operating instructions
Safety-monitoring module
EN
Operating instructions...................... pages 1 to 6
Translation of the original operating instructions
Vous trouverez la version
FR
actuelle du mode d'emploi dans
votre langue nationale oficielle
sur l'Internet, www.schmersal.net.
U vindt de huidige versie van
NL
de gebruikshandleiding in uw
oficiële landstaal op het
Internet, www.schmersal.net.
EU公用語で書かれた最新の
JP
取扱説明書は、インターネッ
(www.schmersal.net)からダウ
ンロードできます。
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2 Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.3 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.2 Sensor coniguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.3 Actuator coniguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.4 Flow diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.5 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Encontrará el manual de
ES
instrucciones actual en su
idioma oicial de la UE en
nuestra página de Internet
www.schmersal.net.
Il manuale d'istruzioni aggiornato
IT
nella vostra lingua (lingua uficiale
UE) è scaricabile in Internet all'in-
dirizzo, www.schmersal.net.
1 About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module. The
operating instructions must be available in a legible condition and a
complete version in the vicinity of the device.

1.2 Target group: authorised qualiied personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical speciications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country-speciic installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Elan
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability. Subject to technical modiications.
The entire concept of the control system, in which the
safety component is integrated, must be validated to
EN ISO 13849-2.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of inadequate or improper use or manipulations of
the safety-monitoring module, personal hazards or damage
to machinery or plant components cannot be excluded. The
relevant requirements of the standard DIN EN 574 must be
observed.
EN
SRB 201ZH X3
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Elan SRB 201ZH X3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal Elan SRB 201ZH X3

  • Page 1 UE en putting the component into operation. sur l’Internet, www.schmersal.net. nuestra página de Internet www.schmersal.net. The machine builder must carefully select the harmonised standards U vindt de huidige versie van Il manuale d‘istruzioni aggiornato...
  • Page 2 Operating instructions Safety-monitoring module SRB 201ZH X3 Pull-in delay for typ. 50 ms 1.7 Exclusion of liability automatic start: We shall accept no liability for damages and malfunctions resulting from Response time: typ. 30 ms defective mounting or failure to comply with this operating instructions Simultaneity monitoring: max.
  • Page 3 Operating instructions Safety-monitoring module SRB 201ZH X3 2.5 Safety classiication 5.2 Description of the terminals Standards: EN ISO 13849-1, IEC 61508, Voltages: +24 VDC EN 60947-5-1, DIN EN 574 A1.1 + 24 V up to e 0 VDC Control category: up to 4 A2.1 ≤...
  • Page 4 Operating instructions Safety-monitoring module SRB 201ZH X3 8.3 Actuator coniguration 7 Disassembly and disposal 7.1 Disassembly Single-channel control with feedback circuit (Fig. 4) • Suitable for increase in capacity or number of contacts by means of The safety-monitoring module must be disassembled in a de-energised condition only.
  • Page 5 Operating instructions Safety-monitoring module SRB 201ZH X3 8.4 Flow diagram Fig. 7 A) Operating voltage U B) Two-hand button A: the representation is related to the potentials at the terminals of the safety-monitoring module; a) NC contact S11; b) NO contact S11; C) Two-hand button B: the representation is related to the potentials at the terminals of the safety-monitoring module;...
  • Page 6 Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. Elan Schaltelemente GmbH & Co. KG Im Ostpark 2, D - 35435 Wettenberg Postfach 1109, D - 35429 Wettenberg Telefon:...

Table of Contents