schmersal SRB303SQP-SS Operating Instructions Manual

schmersal SRB303SQP-SS Operating Instructions Manual

Safety-monitoring module

Advertisement

Quick Links

Operating instructions
Safety-monitoring module
Operating instructions. . . . . . . . . . . . .pages 1 to 6
EN
Original
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
6
6.2 Wiring example: Function SS (Automatic start) . . . . . . . . . . . . . . . .4
6.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.4 Actuator configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7
7.1 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7.2 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7.3 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8
8.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
9
1. About this document
1.1
Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the
safe operation and disassembly of the safety-monitoring module.
The operating instructions must be available in a legible condition
and a complete version in the vicinity of the device.
1.2
Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.
1.3
Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4
Appropriate use
The products described in these operating instructions are developed
to execute safety-related functions as part of an entire plant or machine.
It is the responsibility of the manufacturer of a machine or plant to
ensure the correct functionality of the entire machine or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
1.5
General safety instructions
The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
SRB303SQP-SS
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB303SQP-SS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SRB303SQP-SS

  • Page 1 6.1 Wiring example: Function SQP (External reset button) ..4 Further technical information can be found in the Schmersal 6.2 Wiring example: Function SS (Automatic start) ....4 catalogues or in the online catalogue on the Internet: 6.3 Sensor configuration .
  • Page 2 Operating instructions Safety-monitoring module SRB303SQP-SS Warning about misuse The entire concept of the control system, in which the safety component is integrated, must be validated to the In case of inadequate or improper use or manipulations of relevant standards. the safety-monitoring module, personal hazards or damage to machinery or plant components cannot be excluded.
  • Page 3 Operating instructions Safety-monitoring module SRB303SQP-SS Ambient conditions: 4. Electrical connection Ambient temperature: –25°C … +60°C (non condensing) General information for electrical connection Storage and transport temperature: –40°C … +85°C (non condensing) The electrical connection may only be carried out by...
  • Page 4 Operating instructions Safety-monitoring module SRB303SQP-SS 6. Wiring examples Wiring example: Function SS (Automatic start) Wiring example: Function SQP (External reset button) Dual-channel control, shown for a safety edge • The safety relay module is activated automatically when the feedback Dual-channel control, shown for a safety edge and an external circuit is closed.
  • Page 5 Operating instructions Safety-monitoring module SRB303SQP-SS Actuator configuration 7. Set-up and maintenance Single-channel control with feedback circuit Commissioning • Suitable for increase in capacity or number of contacts by means of The safety relay module features protection class IP54 for installation in contactors or relays with positive-guided contacts.
  • Page 6 Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone:...