1

About this document

11 Function                                              1
12 Target group: authorised qualiied personnel                 1
13 Explanation of the symbols used                           1
14 Appropriate use                                        1
15 General safety instructions                               1
2
25 Safety classiication                                     3
3
32 Dimensions                                           3
4
5
53 Notes                                                3
6
62 Maintenance                                          4
7
71 Disassembly                                          4
72 Disposal                                              4
8
82 Sensor coniguration                                    4
83 Actuator coniguration                                   5
9
91 EC Declaration of conformity                              6
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module The opera-
ting instructions must be available in a legible condition and a complete
version in the vicinity of the device
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machinery or plant
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer Detailed information regarding the range of applications
can be found in the chapter "Product description"
To avoid EMC disturbances, the physical ambient and opera-
tional conditions at the place where the product is installed,
must meet the provisions laid down in the paragraph "Electro-
magnetic Compatibility (EMC)" of DIN EN 60204-1
1.5 General safety instructions
The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all
prevailing safety regulations and accident prevention rules
Further technical information can be found in the online
catalogue on the Internet: wwwschmersalnet
The information contained in this operating instructions manual is provi-
ded without liability and is subject to technical modifications
The entire concept of the control system, in which the
safety component is integrated, must be validated to
EN ISO 13849-2
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed
EN
SRB 201ZH
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB 201ZH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SRB 201ZH

  • Page 1 Set-up and maintenance catalogue on the Internet: wwwschmersalnet 61 Functional testing                                      4...
  • Page 2 Operating instructions Safety-monitoring module SRB 201ZH 1.6 Warning about misuse 2.4 Technical data General data In case of inadequate or improper use or manipulations of Standards: IEC/EN 60204-1, EN 60947-5-1; the safety-monitoring module, personal hazards or damage EN ISO 13849-1, IEC 61508...
  • Page 3 Operating instructions Safety-monitoring module SRB 201ZH 2.5 Safety classification 5. Operating principle and settings Standards: EN ISO 13849-1, IEC 61508, EN 60947-5-1, DIN EN 574, EN 60204-1 5.1 LED functions up to e K1: Status channel 1 Control category: up to 4...
  • Page 4 Operating instructions Safety-monitoring module SRB 201ZH 6. Set-up and maintenance 8.2 Sensor configuration 6.1 Functional testing Two-hand control to DIN EN 574 and EN 60204-1 (see Fig. 3) • Malfunctions of every contact as well as earth leakages and cross-...
  • Page 5 Operating instructions Safety-monitoring module SRB 201ZH 8.3 Actuator configuration 8.4 Flow diagram Single-channel control with feedback circuit (Fig. 5) • Suitable for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts • = feedback circuit: If the feedback circuit is not required, establish a bridge Dual-channel control with feedback circuit (Fig.
  • Page 6 Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at wwwschmersalnet K. A. Schmersal GmbH & Co. KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal...

Table of Contents