schmersal SRB 301/CL1 Operating Instructions Manual

schmersal SRB 301/CL1 Operating Instructions Manual

Safety-monitoring module

Advertisement

Quick Links

Operating instructions
Safety-monitoring module
Operating instructions. . . . . . . . . . . . .pages 1 to 6
EN
Original
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1

1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2 Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.3 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.2 Start configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.4 Actuator configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
9
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module. the
operating instructions must be available in a legible condition and a
complete version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed
to execute safety-related functions as part of an entire plant or machine.
It is the responsibility of the manufacturer of a machine or plant to
ensure the correct functionality of the entire machine or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
The entire concept of the control system, in which the safety
component is integrated, must be validated to EN ISO 13849-2.
EN
SRB 301/CL1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB 301/CL1 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal SRB 301/CL1

  • Page 1 Operating principle and settings Further technical information can be found in the Schmersal 5.1 LED functions......... .3 catalogues or in the online catalogue on the Internet: 5.2 Description of the terminals .
  • Page 2 Operating instructions Safety-monitoring module SRB 301/CL1 2.4 Technical data There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and General data maintenance are observed. Standards: IEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1; IEC 61508 1.6 Warning about misuse...
  • Page 3 Operating instructions Safety-monitoring module SRB 301/CL1 2.5 Safety classification 5.2 Description of the terminals Standards: EN ISO 13849-1, IEC 61508, EN 60947-5-1 Voltages: C +24 VDC/24 VAC Stop 0: up to e 0 VDC/24 VAC Category: Stop 0: up to 4...
  • Page 4 Operating instructions Safety-monitoring module SRB 301/CL1 7. Disassembly and disposal 8.2 Start configuration 7.1 Disassembly External reset button (Fig. 3) The safety-monitoring module must be disassembled in a de-energised • The external reset button is integrated as shown. condition only.
  • Page 5 Operating instructions Safety-monitoring module SRB 301/CL1 8.4 Actuator configuration Single-channel control with feedback circuit (Fig. 7) • Suitable for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. • = feedback circuit: If the feedback circuit is not required, establish a bridge.
  • Page 6 Safety-monitoring module SRB 301/CL1 9. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.

Table of Contents