schmersal SRB301ST/PCV.2 Operating Instructions Manual

schmersal SRB301ST/PCV.2 Operating Instructions Manual

Safety-monitoring module

Advertisement

Quick Links

Operating instructions
Safety-monitoring module
Operating instructions. . . . . . . . . . . . .pages 1 to 8
EN
Translation of the original operating instructions
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.2 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.3 Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.4 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.5 Check of the error detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.6 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
SRB301STV.2 /CCV.2 /PCV.2
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.2 Start coniguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.3 Sensor coniguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.4 Actuator coniguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
9
9.1 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module. The operat-
ing instructions must be available in a legible condition and a complete
version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machinery or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
EN
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB301ST/PCV.2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SRB301ST/PCV.2

  • Page 1 5.4 Functional testing........4 Further technical information can be found in the Schmersal 5.5 Check of the error detection.
  • Page 2 Operating instructions SRB301STV.2 /CCV.2 /PCV.2 Safety-monitoring module SRB301STV.3 /CCV.3 /PCV.3 The entire concept of the control system, in which the To determine the Performance Level (PL) of the entire safety function safety component is integrated, must be validated to (e.g. sensor, logic, actuator) to DIN EN ISO 13849-1, an analysis of all EN ISO 13849-2.
  • Page 3 Dimensions H x W x D: must meet the provisions laid down in the paragraph "Electro- - SRB301ST/PCV.2/V.3: 100 x 22.5 x 121 mm; magnetic Compatibility (EMC)" of DIN EN 60204-1.
  • Page 4 Operating instructions SRB301STV.2 /CCV.2 /PCV.2 Safety-monitoring module SRB301STV.3 /CCV.3 /PCV.3 5.4 Functional testing Setting the switch (see Fig. 3) • The cross-wire short monitoring function (factory setting) is pro- 1. Switch the supply voltage on 2. Open safety switches. grammed by means of the switch underneath the front cover of the 3.
  • Page 5 Operating instructions SRB301STV.2 /CCV.2 /PCV.2 Safety-monitoring module SRB301STV.3 /CCV.3 /PCV.3 7. Disassembly and disposal 8.2 Start configuration 7.1 Disassembly External reset button (monitored start) (see Fig. 5) • The external reset button is integrated in the feedback circuit in series. The safety-monitoring module must be disassembled in a de-energised •...
  • Page 6 Operating instructions SRB301STV.2 /CCV.2 /PCV.2 Safety-monitoring module SRB301STV.3 /CCV.3 /PCV.3 Single-channel guard door monitoring circuit with interlocking The connection of magnetic safety switches to the devices to ISO 14119 (Fig. 10) SRB301ST safety-monitoring module is only admitted when • At least one contact with positive break required. the requirements of the standard EN 60947-5-3 are observed.
  • Page 7 SRB301STV.2 /CCV.2 /PCV.2 Safety-monitoring module SRB301STV.3 /CCV.3 /PCV.3 9. Declaration of conformity 9.1 EC Declaration of conformity EC Declaration of conformity K.A. Schmersal GmbH & Co. KG Translation of the original Declaration of Conformity Industrielle Sicherheitsschaltsysteme Möddinghofe 30, 42279 Wuppertal Germany Internet: www.schmersal.com...
  • Page 8 K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone: +49 - (0)2 02 - 64 74 - 0 Telefax: +49 - (0)2 02 - 64 74 - 1 00 E-Mail: info@schmersal.com...

This manual is also suitable for:

Srb301st/ccv.2Srb301stv.2Srb301st/ccv.3Srb301stv.3Srb301st/pcv.3

Table of Contents