SITRANS F C MASSFLO
2.2.2 Remote installation
Wall mounting
Compact IP 67
version
2. Installation of signal converter
SFIDK.PS.028.M1.02
Mount the wallbracket on a wall, pipe or in the
back of a panel.
Take the SENSORPROM
the sensor. Mount the SENSORPROM
the wall mounting unit as shown. The text on the
SENSORPROM
®
unit must turn towards the
wall bracket.
Mount the connection plate in the terminal box.
Tighten the earthing screw in the centre of the
connection box properly.
Fit the sensor, supply and output cables re-
spectively and tighten the cable glands to ob-
tain optimum sealing. Please see the wiring
diagram for the "Electrical connections".
Mount the signal converter on the terminal box.
®
memory unit from
®
unit in
5