Step 4: Attaching Bucket to Pole
A. Un-screw the hose clamp to release the end and
thread each hose clamp through one of the sets of
narrow center holes in the bucket(s) as shown and
place at the desired location on the pole. Keep the
solid section of the clamp thru the holes on the
bucket.
B. Once the hose clamps are in the desired position,
tighten the hose clamp screws to 35 in-lbs
NOTE: ALWAYS RECHECK TORQUE ON HOSE
CLAMPS AFTER EXPOSURE TO WINDY
CONDITIONS.
Optional mounting hardware (not included)
C. In high loading conditions,
hose clamps, add the
Bolts as appropriate for the pipe size being used ( 2"
to 4" pipe size) Tighten securely but take care not to
deform the bucket
D. Use 1/2" lag bolts as appropriate to a wooden
structure being mounted to (telephone pole or post
Etc.). Tighten securely but take care not to deform
the bucket
E.
Use (optional) hose clamps to attach
buckets to a 25G Rohn tower.
support@tamaracksolar.com
in conjunction with the
optional the optional 1/2-13 U-
1-800-819-7236 Ext 556
Installation Manual
UNI-SP/01A
SOLID SECTION