Electrical data
Camera interface
Ethernet, 1 Gbit/s
(auto-crossover)
X118: 8-pin X-coded M12 flange
socket (female)
Camera
Resolution
Two 1.31-megapixel, monochrome
CMOS image sensors
Operating distance
20.5 mm
Image size
10 mm x 8 mm
Cover glasses
Two
(replaceable using a 3 mm face
spanner)
Light source
Two ring lights with
12 separately controllable LEDs
Two separately controllable
LEDs
Compressed air
Connection
Threaded-plug connection for
8 mm tube
P2: camera 1 + 2
Optional: threaded plug connection
for 6 mm tube
P1: camera 1 + 2
P2: camera 1 + 2
HEIDENHAIN | VT 121 | Operating Instructions | 03/2022
Compressed air
Pressure
Max. 10 bars (145 psi)
≥ 6 bars recommended
Quality
Min. ISO 8573-1:2010 [4:4:4]
Blower jets
Camera 1 + 2
For each camera: one jet block
with seven jets for cleaning the
cover glass
For each camera: one jet block
with two jets for cleaning the
tool
Ambient conditions
Operating
0 °C to +45 °C
temperature
Storage
–20 °C to +60 °C
temperature
Relative air
10 % to 80 % RH, non-condensing
humidity
Altitude
≤ 2000 m
Vibration
200 m/s
EN 60068-2-6)
Shock
300 m/s
EN 60068-2-27)
Sound level
> 85 db(A) inside the working space
(in accordance with
2
(in accordance with
2
49