3. Set scan mode to 100 Hz.
4. Confirm that A, B in Fig. 7 is 6.0 cm ± 1 cm. If not, adjust V-AMP
(100i / 16:9).
5. Set scan mode to progressive.
6. Confirm that A, B in Fig. 7 is 6.0 cm ± 1 cm. If not, adjust V-AMP
(50p / 16:9).
7. Receive NTSC monoscope pattern.
8. Set scan mode to 100 Hz.
9. Confirm that A, B in Fig. 7 is 6.0 cm ± 1 cm. If not, adjust V-AMP
(120i / 16:9).
10. Set scan mode to progressive.
11. Confirm that A, B in Fig. 7 is 6.0 cm ± 1 cm. If not, adjust V-AMP
(60p / 16:9).
6.6. 525p DEFLECTION ADJUSTMENT / CONFIRMATION
6.6.1. V, H-HOLD CONFIRMATION
1. Receive 525p signal.
2. Confirm V, H-hold is normal.
6.6.2. H-CENTER (525p) CONFIRMATION / ADJUSTMENT
1. Receive 525p signal.
2. Copy the data of 00h to EEROM ADDRESS [333] (525p / H-POS).