2. Set scan mode to progressive by remote control key.
3. Adjust the vertical line to straight by Parabola (60p / 4:3).
4. Adjust the vertical line to straight line of both sides vertical line in
Fig. 5 by Trapezoid (60p / 4:3).
5. Confirm there is no H-parallel distortion. / If there is distortion,
adjust by H-Parallel (60p / 4:3). / In that case, repeat 4 and 5 so
that there is no trapezoid / parallel distortion.
6. Confirmation vertical EW of the corner side. / If need, adjust Top-
Corner (60p / 4:3) and Bottom Corner (60p / 4:3).
7. Confirm bow level of the both side. / If it is not symmetrical, adjust
C-Correct (60p / 4:3).
6.4. V LINIALITY ADJUSTMENT / CONFIRMATION (4:3 MODE)
6.4.1. 100i V-Linear ADJUSTMENT
1. Receive PAL monoscope pattern.
Fig. 5