Maintenance (Cont.)
Filter Cartridge Cleaning (Or Replacement)
It is recommended that the filter cartridge be replaced at least every 2 weeks.
1. Make sure the unit is turned off, and disconnect the power cord from the electrical outlet.
2. Grasp a plunger valve handle. Turn the handle counter-clockwise, push down until it stops and
then turn it clockwise until the plastic protruding notch anchors in the "0/1" position. Repeat for the
2nd plunger valve. This prevents the water from flowing out of the pool.
3. Gently turn both air release valves (5F12 & 05F-37) 1-2 turns in a counter-clockwise direction. This
will allow the housing cover to be easily removed.
4. In a counter-clockwise direction remove the filter housing collar (6F16). Place it in a safe location.
5. Remove the housing cover (6F14).
6. Remove the "OLD" filter cartridge.
7. Examine the inside of the filter housing.
8. If dirt or sediment is located on the bottom of the housing then:
A. In a counter-clockwise motion gently unscrew and remove the sediment valve (5F12) located at
the bottom of the housing. Place it in a safe place.
B. With a bucket of water or a garden hose pour water into the housing flushing out the sediment.
C. In a gentle clockwise motion return the sediment valve (5F12) to its location.
Do not over-tighten.
9. Place a new cartridge filter in the housing.
10. Return the housing cover (6F14) to its position and in a clockwise direction rescrew the housing
collar (6F16) onto the filter housing.
11. Turn both plunger valve handles in a counter-clockwise direction, pull up until they stop, and then
turn them clockwise until the metal protruding notch anchors in the "0/1" position.
12. Reconnect the power cord.
13. Turn the unit "ON".
14. When the trapped air has escaped through the air release valves gently retighten the valves
(5F12 & 05F-37) in a clockwise direction.

Long Term Storage

1. Disconnect power cord from electrical outlet.
2. After pool is emptied of all water, disconnect the Saltwater System/Filter Pump from the pool
reversing the installation instructions.
3. Air-dry the unit before storage (It may be prudent to visually inspect and clean the electrolytic cell
at this time).
4. Store the unit and accessories in a dry, cool storage location.
5. The original packing carton can be used for storage.
SAVE THESE INSTRUCTIONS
(104) ENGLISH SALTWATER SYSTEM/FILTER PUMP MODEL8221/8231 SIZE: 7.5" X 10.5" 09/18/2006