Operating Instructions (Cont.)
Saltwater System Operation
After the salt is dissolved, but before starting the chlorine generation be sure that:
The system is connected to a grounding type receptacle protected by a ground-fault circuit
interrupter (GFCI).
The filter pump operates several minutes before starting the Saltwater System (This removes
air pockets and debris in the water hoses).
No air is trapped in any of the hoses. Follow "Filter Pump Operation" above to release any trapped
air.
1. With the Filter Pump turned "ON" and operating. Code "88" appears on the
electronic control station's LED indicating the unit is in a Stand-By Mode, this
is normal.
2. Unlock keypad controls:
Press and hold
button for 5 seconds until you hear a short "beep", then
press and hold
button for another 5 seconds until you hear the second short
"beep", LED flashes "00". This procedure unlocks the keypad control buttons.
3. Set Saltwater System operating hours:
Increase the scheduled number of hours of operation by pressing
button, or reduce by pressing
Table" for pool size and required operating hours. Press
to select hours required, press
The built-in timer will now operate for the number of hours selected
at the same time each day.
NOTE: The Saltwater System will not operate if the filter pump
is not operating.
4. Re-lock keypad controls:
With the proper hour value showing, press and hold
until you hear a long "beep", then press and hold
seconds until you hear the second long "beep". A green LED light on the
control panel will light up within a few minutes, which indicates the saltwater
pool system starting chlorine production. Filter pump can be run alone
without the Saltwater System, with the proper hour value showing,
press and hold both
"beep". With locking the control buttons into this setting you will have prevented
unauthorized changing of the operating cycle.
5. Operating hours can be re-adjusted if necessary. Follow steps 2 thru 4.
6. The scheduled operating hours displayed on the LED readout will decrease to zero as the unit
operates. The LED shows "hours remaining" in the daily operating cycle.
SAVE THESE INSTRUCTIONS
(104) ENGLISH SALTWATER SYSTEM/FILTER PUMP MODEL8221/8231 SIZE: 7.5" X 10.5" 09/18/2006
button. See "Operating Time
if too many hours were selected.
and
buttons for 5 seconds until you hear a long
Page 14
button
(1 to 12 hours max per cycle)
button for 5 seconds
button for another 5