Setting Adjustments - Prince Castle CTD Operation Manual

Vertical contact toasters
Hide thumbs Also See for CTD:
Table of Contents

Advertisement

Change Bun Compression adjustment. Because the
1
platen has separate segments for the "Crown" (left) side
and "Heel" (right) side, they are adjusted separately,
each with its own compression control. For example, if
the heels are slipping through without making good
contact with the platen and look like they need more
toasting, the right compression adjustment switch may
need to be moved to a different letter. Or, if the crowns
seem unusually thick and are being compressed too
much or over-toasted, the left compression adjustment
switch may need to be moved to a different number.
A.
Turn the left-side compression adjustment closer
to "1" to allow for thicker crowns or closer to "10"
for thinner crowns.
B.
Turn the right-side compression adjustment closer
to "A" to allow for thicker heels or closer to "I" for
thinner heels.
Change the Recipe that is
2
running. The unit has four recipes
to choose from. From the
Run/Home screen, you can
change the Recipe that is
currently running.
A.
Press the Recipes icon on
the Run/Home screen. The
Recipes screen will appear.
B.
Press the Left arrow or Right
arrow to change the recipe.
C.
Press the check mark to
accept the change.
NOTE: If you don't want to accept the change, you can
press the Return arrow.
301-500rev02-EN

Setting Adjustments

3
4
5
Vertical Contact Toasters
Change the Temperature set
point. From the Run/Home
screen, you can change the
Temperature set point.
A.
Press the thermometer icon
on the bottom of the
Run/Home screen. The Edit
Run Parameters screen will
appear with the current set
point.
B.
Press the Plus (+) symbol to
increase the set point or the
Minus (-) symbol to
decrease the set point.
C.
Press the check mark to accept the setting.
NOTE: If you don't want to accept the change, you can
press the Return arrow.
Change the Time/Speed set
point. From the Run/Home
screen, you can change the
Time/Speed set point.
Range: 6-40 seconds
Default: 17 seconds
A.
Press the center icon on the
bottom of the Run/Home
screen. The Edit Run
Parameters screen will
appear with the correct set
point.
B.
Press the Plus (+) symbol to
increase the set point or the
Minus (-) symbol to
decrease the set point.
C.
Press the check mark to accept the setting.
NOTE: If you don't want to accept the change, you can
press the Return arrow.
Printed in USA 10/18 © 2018
CTD & CTDE
17

Advertisement

Table of Contents
loading

Table of Contents