Download Print this page

IBM X3630 M4 Manual page 2

Hot-swap rear hdd drive cage option
Hide thumbs Also See for X3630 M4:

Advertisement

Note: If 2U PCI riser-card assemblies are installed in the server, go to step 5.
5. If 2U PCI riser-card assembly are installed in the server, remove all 2U PCI riser-card assembly and
adapters, using the instructions in your server documentation.
6. Install the removed adapters and/or ServeRAID adapter into the relevant 1U PCI riser-card
assembly, using the instructions in your server documentation.
7. Install the 1U PCI riser-card assembly, using the instructions in your server documentation.
8. If an air baffle partition is installed in the air baffle, remove it from the air baffle.
9. Open the two respective blue latches on the chassis 1 .
10. Align the two moveable levers of the rear hard disk drive cage with the two chassis support
brackets. Slide the cage into the chassis support brackets until it firmly sits into place 2 . Then,
rotate the cage inward until it firmly sits into place 3 .
2
Air baffle
Air baffle partition

Advertisement

loading