How Often is Calibration Required?
To achieve optimum quality image, the calibration process should be repeated
under the following conditions:
• Whenever the scanned image is unsatisfactory.
• When either the scanner or LightLid 35 adapter is replaced.
• When the equipment is moved to a new location.
• It is also a good idea to perform the calibration before a day-long scanning
session.
Troubleshooting
If the calibration program encounters problem during execution of the
"Calibrate" command, one of the following error messages will display. Be sure
to uninstall ScanWizard 5 before reinstalling the driver when correcting the
error.
"Load library failed. Could not find msmgr32.DLL!"
ScanWizard 5 missing. Reinstall ScanWizard 5.
"Could not find the scanner driver!"
ScanWizard 5 missing. Reinstall ScanWizard 5.
"Could not find a valid scanner!"
Scanner is not connected to host, or with loose connectors, or has no power.
"The scanner is not ready!"
Scanner to host signal communication (or hand-shaking) error. Refresh
ScanWizard 5.
"Memory allocation error!"
Insufficient RAM. Close other open programs and try again.
"The scanner does not support the shading calibration function!"
Scanner model is not supported, or you have a very old model with out-of-date
firmware.
"The scanner can not perform shading calibration function !"
Check connection between scanner and LightLid 35 adapter, or reset scanner.
"Could not get the scanner capability!"
Fatal error. Reinstall ScanWizard 5.
"Could not get the scanner default attribute!"
Fatal error. Reinstall ScanWizard 5.