Sanuvox BIO-WALL Instruction Manual

Sanuvox BIO-WALL Instruction Manual

Air disinfection system commercial model
Hide thumbs Also See for BIO-WALL:

Advertisement

Quick Links

REGISTER
YOUR WARRANTY
ONLINE AT
www.sanuvox.com
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.
Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit
or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.
1.
Installation and servicing of UV units or systems (in an
air conditioning system or not) can be hazardous. Only
trained and qualified service personnel should install,
repair or service equipment.
2.
Untrained personnel can perform basic maintenance
functions such as replacing lamp(s) and/or filter(s). All
other operations should be performed by trained service
personnel.
3.
The unit is not to be used by persons (including children)
with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge.
CAUTION: Unit is not a toy. Keep away from
unsupervised children. Do not leave children unattended
with the unit.
4.
DO NOT hang onto the UV unit or system.
5.
Some UV units or systems could be heavy: Make sure
you have a minimum of 2 people to safely move or install
these UV units or systems, and make sure you adopt the
most ergonomic position possible (use UV unit or system
handles, if applicable).
CAUTION: Installing or maintaining heavy equipment,
especially overhead, can cause back pain or other injuries.
6.
When installing or servicing an overhead UV unit or system,
be careful not to fall off the stepladder. Furthermore, make
sure the UV unit or system latches are always in place to
prevent falling parts.
CAUTION: Some parts of some UV units and systems
may open suddenly if the UV unit or system is installed
high up without its locks.
6.1.THIS AIR CLEANER SHALL NOT BE INSTALLED ON THE
HOT-AIR SIDE OF DUCT-TYPE SYSTEMS.
Installation Date: _______________
Installer Contact Info.: _________________________________________
BIO-WALL™
AIR DISINFECTION SYSTEM
Commercial Model

IMPORTANT SAFETY INSTRUCTIONS

NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP.
7.
Units that are obviously damaged must not be operated.
8.
CAUTION: When working on the UV unit or system,
observe precautions on the literature, tags and labels
attached to the UV unit or system, and all other safety
precautions considered as best practices in the HVAC
industry, if applicable.
9.
When applicable, local regulation may comprise more
restrictive installation and/or certification requirements.
The aforementioned requirements prevail on those of this
document and the installer agree to conform to these at his
own expense.
10. Follow all the safety instructions outlined in this document
and respect all local and national codes applicable.
11. All UV units or systems contain a UV-C source. Damage to
the housing or unintended use of the UV unit or system may
result in harmful UV-C leaks. UV-C may, even in little doses,
cause harm to the eyes and skin.
12. Never expose eyes or skin to an operating UV lamp.
Therefore, before installing or performing maintenance
on the UV unit or system, TURN OFF AND DISCONNECT
the UV unit or system from all power sources (there
may be more than one switch to disconnect) and also
disconnect the HVAC system, is applicable.
CAUTION: Electrical shock may cause injuries or
possibly death. FIRST AID INSTRUCTIONS: If injured,
consult a doctor.
13. UV rays may damage certain types of filters (polymer or
plastic); please keep the UV unit or system light away from
shining directly on plastic.
Sanuvox Technologies Inc, © 2019 All rights reserved. January 2023 EN v.2
14. When installing or performing maintenance on the UV unit
or system, it is recommended to wear safety gloves. In
order to avoid reduced performance of lamp(s), do not
touch lamp glass without gloves.
15. Just like conventional fluorescent lamps, UV lamps contain
a small quantity of mercury: if a lamp breaks, clean and
dispose of with care. UV lamps can be disposed/recycled
after use in the same way as any other fluorescent lamps.
Contact and follow the specific instructions of your local
and national authorities.
16. Use only specified SANUVOX branded replacement
UV lamps for your UV unit or system. Use of any other
lamps will void your warranty and can result in damage to
the UV unit or system.
17. Sanuvox UV units or systems are not waterproof. DO NOT
INSTALL OUTDOORS OR IN WET LOCATION unless
specified otherwise.
18. The use of a UV unit or system is a supplement to and
not a substitute for standard infection control practices;
users must continue to follow all current infection control
practices, including those related to the cleaning and
disinfection of environmental surfaces.
For any inquiries on a UV unit or system, contact :
Installed by: _________________
Instruction Manual
SAVE THESE INSTRUCTIONS
Robert Smith
146 Barr St, Saint-Laurent
Quebec, CA, H4T 1Y4
1-888-726-8869
techsupport@sanuvox.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BIO-WALL and is the answer not in the manual?

Questions and answers

Summary of Contents for Sanuvox BIO-WALL

  • Page 1: Important Safety Instructions

    1-888-726-8869 6.1.THIS AIR CLEANER SHALL NOT BE INSTALLED ON THE techsupport@sanuvox.com HOT-AIR SIDE OF DUCT-TYPE SYSTEMS. Installation Date: _______________ Installed by: _________________ Installer Contact Info.: _________________________________________ Sanuvox Technologies Inc, © 2019 All rights reserved. January 2023 EN v.2...
  • Page 2: Table Of Contents

    Instruction Manual for BIO-WALL™ TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS TABLE OF CONTENTS ABOUT THE PRODUCT AVAILABLE MODELS COMPONENTS How it Works ACCESSORIES & KITS SETUP & INSTALLATION What you will need What’s included Setup Step by Step Installation ELECTRICAL DIAGRAM...
  • Page 3: About The Product

    HVAC system of the building or facility. The BIO-WALL™ is installed in the RETURN (preferred) or SUPPLY plenum of the HVAC system purifying the air passing through the air duct. The actual percentage of destruction obtained is based on the duct size, percentage of fresh air, velocity, the number of passes and specific contaminants to be treated.
  • Page 4: Accessories & Kits

    Setup While selecting the appropriate location for your BIO-WALL™, refer to your customized sizing and placement proposal. If you do not have the customized proposal, call SANUVOX at 1-888-726-8869 to obtain one at no-charge. The ballast boxes are to be installed on the outside of the air central in a dry area.
  • Page 5: Step By Step Installation

    STEP 1 1. Select where the BIO-WALL™ extrusion will be installed. The location requires a straight duct of a minimum length without obstruction. Refer to the table below according to the length of the BIO-WALL™ to be installed. Length required...
  • Page 6 Instruction Manual for BIO-WALL™ STEP 5 Assemble BIO-WALL™ Supports 5. Start by measuring the height of the duct. Then cut two pieces of support pipe this height – minus 1.5" (3.8 cm) to accommodate the mounting flanges. STEP 6 6. Insert a clamp assembly on each section and tighten it in the center with the bolts provided for this purpose.
  • Page 7 Instruction Manual for BIO-WALL™ STEP 12 12. Slip the end of the cable through the hole and gently pull the cable out of the conduit. NOTE: At some point, you will be in a position to lift the extrusion and gently slide it into the mounting clips.
  • Page 8 WALL™. Be sure to identify the correct one. Furthermore, if you wish to share the information with a management controller, SANUVOX offers 3 BMS operating modes: an external 24 VDC power supply will be required. Please refer to the “OPERATION”...
  • Page 11: Operation

    If the lamp is working, the signal read will be VCC. The installer/user must supply 0V and VDC (5V to 24V) to the PCB. NOTE: For the BIO-WALL™ to work in Mode 1, it is necessary that 7 wires are connected between the electronic card and the BMS. MODE 2 BIO-WALL™...
  • Page 12: Step By Step Change Of Operation Mode

    Instruction Manual for BIO-WALL™ Step by Step Change of Operation Mode FIG. 1 By default 1. Turn off the power at the ballast box. 2. Remove the cover by turning the 4 screws to the left. 3. Locate the section in Figure 1.
  • Page 13: Maintenance

    Lamps should be replaced every 2 years to maintain design specifications. Replacing the lamps of a BIO-WALL™ is quick and easy. Turn off the power source. Remove and dispose of old lamps as you would regular fluorescents. Replace new SANUVOX brand UV lamps. Turn the power source back on.
  • Page 14: Step By Step Lamp Timer Reset

    ULTRAVIOLETS: UVC The UVC (254 nm) wavelengths produced by Sanuvox UV units and systems are the same as the ultraviolets produced by the Sun. The UVC attacks the micro-organisms on a molecular level deactivating the contaminants. Unlike conventional UV lamps on the market, Sanuvox UV units and systems use a patented process designed to deliver the maximum UV dosage to the moving airstream or surface.
  • Page 15: Range Of Environmental Considerations

    Access to LEDs When the BIO-WALL™ is not used with the BMS hookup or BioSmart display (optional), your only way to determine if the lamps or fans are working is by looking at the LEDs inside the BIO-WALL™ ballast box.
  • Page 16: Warranty

    This warranty applies only to the original purchaser of this product from the original date of purchase. At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.

Table of Contents