Troubleshooting guide for Bio-Wall WARNING Disconnect all power sources before servicing or touching any internal components Sanuvox Technologies, Montréal www.sanuvox.com April 2017...
Table of content List of tools needed for troubleshooting ...................... 3 Electrical box of the Bio-Wall MAX ....................... 3 Circuit board of the Bio-Wall MAX ........................ 3 Introduction ..............................4 Identification of status mode ........................4 Troubleshooting ............................5 Step by Step ..............................7...
List of tools needed for troubleshooting Flat head screwdriver OHM meter Electrical box of the Bio-Wall MAX Circuit Ballasts Terminal block Fans Circuit board of the Bio-Wall MAX Ballast connections Ballast status Fans Power Switch Jumper connections connection...
Ballast status Identification of status mode 1. Disconnect power form the Bio-wall MAX and wait 5 seconds 2. Reconnect the power (LEDs will flash red/green for 5 seconds) 3. All LED will turn red except one LED that will be green which corresponds to the status mode Figure 1 - Mode 2 sélectionné...
The breaker is not ON • electrical appliance. The PCB is damaged • Make sure the breaker is ON • Contact Sanuvox for a new PCB • Some LEDs are red The lamp or ballast where Led is Replace lamp or ballast • •...
Page 6
Some lamps do not Lamp is defective Change a working lamp with the • • come ON defective lamp to confirm a lamp Ballast is defective • out or ballast out Connection between ballast and • Verify wire connection between •...
Are both fans working? To prevent overheating of internal See instructions to Call Sanuvox replace lamp or ballast components It is important 1 out of 2 fans is working at all times.Verify that fans are connected properly and that theycan turn freely.