Global BEAT-Tr User Manual page 17

Electrofusion control box
Table of Contents

Advertisement

USER MANUAL
Range BEAT-Tr
REV. VALID UNTIL
dd/mm/yy
If the date dd/mm/yy has not expired yet, press START to confirm and proceed to the
next screen (regardless of the existing locking set up of the unit).
If the date dd/mm/yy has already expired but the unit is set up without locking, by
pressing START you will be able to move to the next screen. However, if the unit is set
up with locking subsequently the unit will not be able to be used until the TMS has been
carried out.
AMBIENT TEMPERATURE OUT OF RANGE
If the ambient temperature is not within -20
the ambient temperature can be set according to the required company specifications;
check current temperature setting] or the temperature sensor is defective, with data entry
via bar code the following message will be displayed:
TEMPERATURE
OUT OF RANGE
NOTE: In the case of faulty probe, send the unit to an authorised STPAcuster group After-
sale Service.
INTERNAL FAULT
If the software detects that there is a voltage output through the electrofusion cables out
of the electrofusion cycle, the display shows the following message:
SERIOUS TROUBLE
TURN OFF UNIT
NOTE: If case to have an electrofusion fitting connected, check if it has suffered damage.
Send the unit to an authorised STPAcuster group After-sale Service.
LOW BATTERY
In case to detect a battery voltage below the minimum required, the display will indicate:
SERVICE
FLAT BATTERY
Pressing the START button, the display shows the date and time to update it (refer to
paragraph DATE/TIME of section 3.2.4 of this Manual). This update will keep for some
time if the battery is not replaced, especially with the unit disconnected from the mains.
From the time the unit is started up, a verification of the input voltage is performed. If the
voltage registered by the unit is above or below the tolerance allowed (195-265 V for
nominal 230Vac and 90-140 V for nominal 110Vac ), one of the following messages will
appear on the display:
Edition: January 2016
Revision: No. 3
The unit will emit an acoustic signal and a message will
appear in the display along with the date of the next check.
/
C and 50
Pressing the key START/VALIDATE automatically
switches to manual mode.
The unit will be blocked and the buzzer will be permanently
activated. Switch off immediately the unit.
Send the unit to the STPAcuster group After-sale Service
for the replacement of the battery.
/
C [from software version v. 1.32
MODE OF USE - 17