Stadler Form Roger Operating Instructions Manual page 65

Hide thumbs Also See for Roger:
Table of Contents

Advertisement

TR-KKL-2020-102 dated 1 December 2020
Product Test on a Pleated Combi Filter Element based DIN 71460-1:2006
Stadler Form, Pleated Combi Filter Element
2.2
Test conditions and procedure
Boundary condition of the test:
• Test volume flow:
• Dust concentration:
• Test dust:
• Air temperature:
• Air humidity:
• Drying for 24 h in a climate cabinet at 60 °C.
• Equilibration inside the test channel at rated volume flow for 15 min
The determination of the differential pressure loss curve and the dust holding capacity
were not part of the order.
2.3
Measurement equipment
Measurement equipment installedfor the test:
• Particle counter:
• Particle disperser:
• Differential pressure:
• Rel. humidity/Temperature: "SD700" of Extech Instruments
• Dilution device:
• Volume flow:
290 m³/h
75 ± 5 % mg/m³
A2 fine (ISO 12103-1)
23 ± 2 °C
50 ± 3 %
"Welas 300" of Palas
"RBG 2000" of Palas
"ManoAir 500" of Schildknecht
"VKL-10" of Palas
"Inlet Nozzle" of Westenberg
S y s t e ms
Page 4 of 6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Roger littleRoger big

Table of Contents