Download Print this page
Waterdrop WD-UA Installation Instructions
Waterdrop WD-UA Installation Instructions

Waterdrop WD-UA Installation Instructions

Direct connect undersink water filtration system

Advertisement

Quick Links

Direct Connect Undersink Water Filtration System
WD-UA system | Installation Instructions
System certi ed by WQA against NSF/ANSI Standards 42 for the reduction of the claims
speci ed on the Performance Data Sheet, and to NSF/ANSI 372 (≤0.25% lead).
Filter head
Outlet hose
Inlet hose
Teflon tape
3/8"-1/2" converter
Specifications
Operating temperature
2-38℃/35-100℉
Working pressure
10-100psi (0.7-6.8bar)
Flow rate
0.75gpm (2.83lpm)
WD-RF10/WD-RF10-UF/MZ/AK: up to 11,000 gallons
Filter capacity
WD-RF15/WD-RF15-UF/MZ/AK: up to 19,000 gallons
WD-RF17/WD-RF17-UF/MZ/AK: up to 24,000 gallons
Feed water requirement
Municipal tap water
Note:
1. If using well water as the source, please make sure the feed water has been through a pre- ltration system, otherwise,
large particles in well water will clog the lter easily and shorten lter life.
2. The above form lists model numbers of only black lters. Please note that the white lter is di erent from the black
lter only in color. They have the same lter material and ltration capacity.
3. Actual lter life varies according to local water quality.
Precautions
• Do not use it with water that's microbiologically unsafe or of unknown quality without adequate disinfection.
• For use only with cold water.
• Do not freeze the lter, as this can cause cracking and water leakage.
• Do not allow children under 3 years old to have access to small parts during installation of this product.
• This installation must comply with all applicable state and local regulations.
• Turn o the water supply while replacing the lter.
Installation of the filter system
Step 1: Fix the filter head and the filter
1. Paste the assistant label to nish drilling. (Note: Mount the water lter at
least 2 inches higher than the ground for easier lter change.)
2. Install the screw and reserve enough space to hang the lter.
3. Hang the lter system on the screw.
Step 2: Connect the water supply (cold water only)
1. Connect the inlet hose and the outlet hose to the lter head. (Figure 1)
Note: When the hose is tightly inserted, there will be a 1/8 inch gap between the hose and the lter
head, which is designed for easy replacement and won't a ect the sealing performance.
2. Shut o the water supply. Remove the faucet hose. (Figure 2)
Figure 1
Figure 2
Inlet hose
outlet hose
3. Connect the inlet hose to the cold water valve.
• If the angle valve outlet is 3/8", it can be directly connected to the water supply. (Figure 3)
• If the angle valve outlet is 1/2", connect it with a No.1 converter at rst. (Figure 4)
Figure 3
Figure 4
1/2" outlet
3/8" outlet
Connect ① to the cold angle valve
Step 3: Connect to the faucet
1. If the angle valve outlet is 3/8", it can be directly connected to the water supply. (Figure 5)
2. If the angle valve outlet is 1/2", connect it with a No.2 converter at rst. (Figure 6)
Figure 5
Note: If a female threaded connector is needed, please contact our service team for help.
Check the leaks and flush the filter
1. If water leakage occurs, turn o the water supply. If the water leakage is occurring at position 1 and 2,
wrap Te on tape on the external thread. If the water leakage is occurring at position 3 or 4, insert the
quick-connect tting to the end and make sure the hoses hit the bottom of the tting.
2. Flush the lter for 5 minutes before use.
To disconnect
Use your thumb and index nger to press down on the lock sleeve. Use your other hand to pull out the
hose from the tting.
Note: Please do not pull out the tubing directly, or else it will damage the tting and cause leakage.
Figure 6
Faucet hose
Faucet hose
Outlet hose
Faucet hose
1
Inlet hose
2
3
4
Outlet hose
Hot
Cold
Filter system
Press
Pull
Press

Advertisement

loading

Summary of Contents for Waterdrop WD-UA

  • Page 1 1. Paste the assistant label to nish drilling. (Note: Mount the water lter at least 2 inches higher than the ground for easier lter change.) WD-UA system | Installation Instructions 2. Install the screw and reserve enough space to hang the lter.
  • Page 2 Substance Inf. Average Speci ed Challenge Concentration Ave. % Reduction A: The main purpose of this waterdrop lter is not to remove TDS. TDS stands for total dissolved solids, Chlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10% 92.7% and it is basically composed of inorganic salts and a small amount of organic matter.

This manual is also suitable for:

Wd-10uaWd-17uaWd-15ua