S+S Regeltechnik RYMASKON 200-Modbus User Manual page 35

Modbus slave, room control units
Hide thumbs Also See for RYMASKON 200-Modbus:
Table of Contents

Advertisement

®
RYMASKON
200-Modbus
Modbus Slave User Manual
Register Name
config_display_
value_13
config_display_
value_14
config_display_
value_15
Table 27: Display Value Configuration
© S+S REGELTECHNIK GMBH | THURN-UND-TAXIS-STR.22 | 90411 NÜRNBERG | GERMANY | FON +49(0)911 519470
Register
Address
15
14
13
282
unit_modbus
0x011A
[0x0]
283
VSA
VEU
DSSA
0x011B
[0]
[0]
[0]
284
unit_modbus
0x011C
[0x0]
285
VSA
VEU
DSSA
[0]
[0]
[0]
0x011D
286
unit_modbus
0x011E
[0x0]
287
VSA
VEU
DSSA
[0]
[0]
[0]
0x011F
These registers hold the configuration of the 16 display values.
semantic_meaning:
is used to provide information about the semantic meaning and the source of
the value. For further information please see Table 29 on Page 38.
CAL:
if set to '1' the corresponding offset_value can be edited in
CALIBRATION-mode (only capable if DSEU or DSSA is set to '1')
unit:
defines a unit with which the corresponding display value appears on the
LCD
unit_modbus:
defines a unit that the corresponding display value register appeare on
Modbus
!!! For both, unit and unit_modbus the following values are possible:
0x0
0x1
0x2
0x3
no
°C
°F
cfm
unit
Bits 0-11 of the higher address of each configuration register indicate the symbols that are displayed along
with the corresponding display value.
DSEU: Display Source for End User
DSSA: Diplay Source for System Administrator
These two bits define if the value displayed is taken from a display_value register at address 64 to 79 (see
Table 11 on Page 22) or from a sensor_value register at address 48 to 56 (see Table 10 on Page 21).
The following states are valid:
0 – defines that the value is taken from a display_value register that has to be set via modbus.
1 – defines that the value is taken from a sensor_value (+ offset_value) register that is automatically
updated with the current sensor value.
VEU: Visible for End User
VSA: Visible for System Administrator
These two bits define if the display value is visible for the end user and/or the system administrator.
If set to '1' the value will be visible.
Table 30
!!! See
on Page 40 for example configurations of display values or set points.
Bit Position
12
11
10
9
8
unit
[0x0]
DSEU
[0]
[0]
[0]
[0]
[0]
unit
[0x0]
DSEU
[0]
[0]
[0]
[0]
[0]
unit
[0x0]
DSEU
[0]
[0]
[0]
[0]
[0]
0x4
0x5
0x6
0x7
l/s
m³/h
Pa
inWC V
Page 35 of 55
7
6
5
4
3
semantic_meaning
CAL
[0]
[0x00]
[0]
[0]
[0]
[0]
[0]
semantic_meaning
CAL
[0]
[0x00]
[0]
[0]
[0]
[0]
[0]
semantic_meaning
CAL
[0]
[0x00]
[0]
[0]
[0]
[0]
[0]
0x8
0x9
0xA
0xB 0xC
%
%RH
ppm °F dec.
2
1
0
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
|www.SplusS.de

Advertisement

Table of Contents
loading

Table of Contents