Integra MINI 96 Quick Start Manual

Integra MINI 96 Quick Start Manual

96 channel pipette
Hide thumbs Also See for MINI 96:

Advertisement

Quick Links

Quick Start Guide
This quick start guide is intended to provide a quick overview of your MINI 96's
key features and to offer basic instructions for getting started. For detailed
information, please refer to the latest operating instructions that can be found at
www.integra-biosciences.com
Use this QR code or visit
started

Intended use

This is a general-purpose laboratory instrument. Any use of this instrument in a medical or IVD
setting is the sole responsibility of the user. MINI 96 are electronic handheld pipettes that can be
used for aspirating and dispensing aqueous solutions in the volume range of 0.5 μl to 1250 μl using
GRIPTIPS® pipette tips only, see www.integra-biosciences.com.

Safety information

Regardless of the listed safety notes, all locally applicable regulations must be observed.
1) The pipette may only be used by properly trained personnel in a manner specified by INTEGRA
Biosciences.
2) Do not use the instrument near flammable material or in an atmosphere with danger of
explosion.
3) Do not immerse the pipetting unit in liquid. Avoid pipetting of liquids emitting corrosive vapors.
4) Servicing work and repairs may only be performed by INTEGRA Biosciences or an authorized
after-sales service member.

Getting started

Hold the MINI 96 by the carrying grip and handle (a, g) and set it up on a perfectly
horizontal surface.
For shipping the instrument, clear the deck, select park head and press OK. The
pipetting unit automatically moves to park position. Use the original packaging.
Insert the adapter cable in the socket (l) and connect the mains adapter to the electricity mains.
–  
 240 VAC, 50 
Supply voltage: 100
f
e
d
c
b
a
129951_V02_QSG_MINI_96.docx
to access the getting started video.
 60 Hz
.
g
a. Carrying grip
b. Base stage on deck
h
c. Magnetic covers, for second stage
d. LED bars
e. Deck light
f. Control unit
g. Carrying handle
h. Pipetting unit, to move up and down
i.
AUX port
i
j.
USB-C port
j
k. Main switch (ON ǀ OFF)
k
l.
DC Input for mains adapter
k l
MINI 96 − 96 Channel Pipette
in different languages.
www.integra-biosciences.com/en/mini-96-getting-
1/4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MINI 96 and is the answer not in the manual?

Questions and answers

Summary of Contents for Integra MINI 96

  • Page 1 Getting started Hold the MINI 96 by the carrying grip and handle (a, g) and set it up on a perfectly horizontal surface. For shipping the instrument, clear the deck, select park head and press OK. The pipetting unit automatically moves to park position.
  • Page 2 MINI 96 control unit m. Display n. Touch wheel, spin to scroll the cursor o. OK button, to make a selection p. RUN button, to start operations q. Tip ejector r. PURGE button, to empty tips s. Arrow buttons, for selections t.
  • Page 3 Always switch off the device and disconnect from the electricity supply when carrying out maintenance work. Clean the MINI 96 housing with a lint-free cloth lightly soaked with mild soap solution in distilled water or with a 70 % solution of isopropanol or ethanol.
  • Page 4 The device may be decontaminated with H gas (maximal concentration 35 %) for 60 minutes. If you intend to ship the MINI 96 to be periodically calibrated, the original packaging can be stored and reused for this purpose. Contact INTEGRA for more information about calibration services.

This manual is also suitable for:

4801480248034804

Table of Contents