Archangel Installation Guide
Use the 10 mm spacer block to ensure that the floor channel is aligned with the wall channel, push the
ends together and tape in position.
Remove the 10mm spacer and apply a generous amount of silicone into the corner joint formed by
the two channels.
Reinsert the noted rubber strips into the floor channel.
As shown, run a bead of silicone along the inside walls of the floor and wall channels.
Using the suction lifters, replace the glass panel into the silicone lined channels.
To prevent leakage around the wall brackets, fill the glass slot at the lower bracket with silicone.
Loosely fix the faceplates of the glass-to-wall brackets through the holes in the glass, ensuring
that the clear plastic gaskets are inserted to both sides of the glass.
Fully tighten the bracket wall screws.
Ensure that the glass panel is vertical in the correct position, then tighten the wall bracket face
plates.