ProCurve 9408sl Quick Start Manual page 7

Routing switch
Hide thumbs Also See for 9408sl:

Advertisement

2. Copy the PBIF image from the TFTP server or a flash card in slot 1 or 2 to all interface modules or an interface
module in a specified chassis slot. To perform this step, enter one of the following commands at the Privileged
EXEC level of the CLI:
copy tftp lp <ip-addr> <image-name> fpga-pbif all [<module-type>]
copy tftp lp <ip-addr> <image-name> fpga-pbif <chassis-slot-number>
copy slot1 | slot2 lp <image-name> fpga-pbif all [<module-type>]
copy slot1 | slot2 lp <image-name> fpga-pbif <chassis-slot-number>
If you specify the module-type (e.g., 4x10g), the ProCurve 9408sl copies the PBIF images for that particular
module only. If you specify all without a module-type, the system copies the appropriate PBIF images to their
corresponding modules.
For software version 02.1.00c, the "image-name" filename is "pbif02100c.bin".
3. Copy the XTM image from the TFTP server or a flash card in slot 1 or 2 to all interface modules or an interface
module in a specified chassis slot. To perform this step, enter one of the following commands at the Privileged
EXEC level of the CLI:
copy tftp lp <ip-addr> <image-name> fpga-xtm all
copy tftp lp <ip-addr> <image-name> fpga-xtm <chassis-slot-number>
copy slot1 | slot2 lp <image-name> fpga-xtm all
copy slot1 | slot2 lp <image-name> fpga-xtm <chassis-slot-number>
For the XTM image, there is no option to specify "module-type".
For software version 02.1.00c, the "image-name" filename is "xtm02100c.bin".
4. Copy the XPP image from the TFTP server or a flash card in slot 1 or 2 to all interface modules or an interface
module in a specified chassis slot. To perform this step, enter one of the following commands at the Privileged
EXEC level of the CLI:
copy tftp lp <ip-addr> <image-name> fpga-xpp all [<module-type>]
copy tftp lp <ip-addr> <image-name> fpga-xpp <chassis-slot-number>
copy slot1 | slot2 lp <image-name> fpga-xpp all [<module-type>]
copy slot1 | slot2 lp <image-name> fpga-xpp <chassis-slot-number>
If you specify the module-type (e.g., 4x10g), the ProCurve 9408sl copies the XPP images for that particular
module only. If you specify all without a module-type, the ProCurve 9408sl copies the appropriate XPP images
to their corresponding modules.
For software version 02.1.00c, the "image-name" filename is "xpp02100c.bin".
5. Copy the XBRIDGE image from the TFTP server or a flash card in slot 1 or 2 to all interface modules or an
interface module in a specified chassis slot. To perform this step, enter one of the following commands at the
Privileged EXEC level of the CLI:
copy tftp lp <ip-addr> <image-name> fpga-xbridge all [<module-type>]
copy tftp lp <ip-addr> <image-name> fpga-xbridge <chassis-slot-number>
copy slot1 | slot2 lp <image-name> fpga-xbridge all [<module-type>]
copy slot1 | slot2 lp <image-name> fpga-xbridge <chassis-slot-number>
If you specify the module-type (e.g., 1gx60-gc-v6), the ProCurve 9408sl copies the xbridge images for that
particular module only. If you specify all without a module-type, the ProCurve 9408sl copies the appropriate
xbridge images to their corresponding modules.
For software version 02.1.00c, the "image-name" filename is "xbridge02100c.bin".
F. Rebooting the Management Module
After upgrading the software images on the management and interface modules, you must reboot the management
module. After the management module reboots, it in turn reboots the interface modules.