2. Copy the new monitor-and-boot-image file to the ProCurve 9408sl management module. Enter one of the
following commands at the Privileged EXEC level of the CLI:
Table 1: New Command Syntax for Upgrading Monitor and Boot Images
Command Syntax
copy tftp flash <ip-addr> <image-name> mon copy-boot
copy slot1 | slot2 flash <image-name> mon copy-boot
a.These commands are supported in software releases 02.0.00 and later.
For software version 02.1.00c, the "image-name" filename is "mb02100c.bin".
3. Verify that the new monitor and boot images have been successfully copied to flash by using the show flash
command. Check for the boot image, monitor image, and the date and time at which the new images were built.
B. Upgrading the Management Module's ProCurve Software Image
To upgrade the management module's ProCurve software image (primary or secondary), perform the following steps:
1. Place the new ProCurve software image on a TFTP server to which the ProCurve 9408sl system has access
or on a PCMCIA flash card inserted in slot 1 or 2.
2. Copy the new ProCurve software image from the TFTP server or a flash card in slot 1 or 2 to the management
module's code flash. To perform this step, enter one of the following commands at the Privileged EXEC level
of the CLI:
copy tftp flash <ip-addr> <image-name> primary | secondary
copy slot1 | slot2 flash <image-name> primary | secondary
For software version 02.1.00c, the "image-name" filename is "mpr02100c.bin".
3. Verify that the new ProCurve software image has been successfully copied to the specified destination by using
the show flash command. Check for the primary or secondary image ("Application Image") and the time that
the image was built.
C. Upgrading the Interface Module's Monitor and Boot Images
Software releases 02.0.00a and later enable you to upgrade an interface module's monitor and boot images
simultaneously. Both images are contained in a single file, which is placed in both the boot flash and the code flash.
To upgrade an interface module's monitor and boot images simultaneously, perform the following steps:
1. Place the new monitor-and-boot-image file on a TFTP server to which the system has access or on a PCMCIA
flash card inserted in slot 1 or 2.
4
on the Management Module
a
Description
Copies the "image-name" file from a
TFTP server at "ip-addr" to both the
monitor file in code flash and the
boot file in boot flash.
Copies the "image-name" file from a
flash card in slot 1 or 2 to both the
monitor file in code flash and the
boot file in boot flash.