Interconnection; Connection; Wiring - Siemens sitrans WS100 Instruction Manual

Speed sensor
Hide thumbs Also See for sitrans WS100:
Table of Contents

Advertisement

Interconnection

Note:
Installation shall be performed only by qualified personnel and in
accordance with local governing regulations.
Connection between the SITRANS WS100 standard unit and the integrator should be
made with three-wire shielded, 0.324 mm
To connect the SITRANS WS100 IS unit to the switch isolator, use two-wire shielded
²
0.324 mm
(22 AWG) cable. Use the same cable to connect the switch isolator to the
integrator.
Ground the shield at the integrator end ONLY.
Notes:
Flexible conduit is recommended so that excess stress is not applied to the
shaft bearings.
Use appropriate conduit and conduit fittings or cable glands to maintain local
approvals.

Connection

WS100 standard
WS100 standard
red
white
black
WS100 IS
WS100 IS
brown
blue

Wiring

Red – +V DC
The positive power supply from the integrator connection.
White – Speed Out
The positive output connection of the measurement loop.
7ML19985LU01 SITRANS WS100 Speed Sensor – INSTRUCTION MANUAL
Integrator
speed excitation
speed signal
speed common
IS Switch Isolator
Terminal
1
3
7
8
²
(22 AWG) cable.
Integrator
speed signal
speed common