Leroy-Somer Nidec LSA 50.2 Installation And Maintenance Manual
Leroy-Somer Nidec LSA 50.2 Installation And Maintenance Manual

Leroy-Somer Nidec LSA 50.2 Installation And Maintenance Manual

Low voltage alternator - 4 pole

Advertisement

Quick Links

LSA 50.2
Low Voltage Alternator - 4 pole
Installation and maintenance

Advertisement

Table of Contents
loading

Summary of Contents for Leroy-Somer Nidec LSA 50.2

  • Page 1 LSA 50.2 Low Voltage Alternator - 4 pole Installation and maintenance...
  • Page 2 Warning symbol for general danger to of the generator, sized to interrupt the personnel. fault current. © 2022 Moteurs Leroy-Somer SAS Share Capital: 38,679,664 €, RCS Angoulême 338 567 258. Warning symbol for electrical danger to We reserve the right to modify the characteristics personnel.
  • Page 3: Table Of Contents

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole CONTENTS 1 - RECEIPT ......................4 1.1 - Standards and safety measures .................4 1.2 - Inspection ........................4 1.3 - Identification .......................4 1.4 - Storage ........................4 1.5 - Applications ........................4 1.6 - Usage restrictions ......................4...
  • Page 4: Receipt

    NEMA MG1 - 32 & 33 415 v / 40°C Std by. DE bearing 27°C NDE bearing MOTEURS LEROY-SOMER 2 BD MARCELLIN LEROY - 16000 ANGOULÊME - FRANCE www.leroy-somer.com Scan the code or go to GEN.LS1.DO Made in Europe by Leroy-Somer to check product data...
  • Page 5: Technical Characteristics

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole 2 - TECHNICAL 2.2 - Mechanical characteristics CHARACTERISTICS - Steel frame - Cast iron end shields 2.1 - Electrical characteristics - Protected ball bearings, greased for life This alternator is a machine without - Mounting arrangement: single bearing...
  • Page 6: Installation

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole 3 - INSTALLATION • Single-bearing coupling Before coupling, check the compatibility Personnel undertaking various between the alternator and the engine by operations indicated in this section must performing: wear personal protective equipment...
  • Page 7: Terminal Connection Diagrams

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole 3.3 - Terminal connection diagrams There are 2 possible methods for restoring the above minimum values. To modify the connection, change the a) Dry out the machine for 24 hours in a position of the stator cables on the terminals.
  • Page 8 Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole • AREP or PMG three-phase 6-wire Voltage / Detection Connection codes Factory connection 50 Hz 60 Hz Winding L1(U) 380 - 415 380 - 480 L3(W) L2(V)
  • Page 9 Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole • Option connection diagram Remote voltage potentiometer 1000 ohms Voltage adjustment via remote potentiometer Current transformer connection Thermistor temperature (PTC) Anti condensation heater Coupling D In/4 - Secondary 1 A...
  • Page 10: Commissioning

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole • Connection checks 3.4 - Commissioning Electrical installations must comply with the current legislation in force in the The machine can only be started up and country of use.
  • Page 11: Servicing - Maintenance

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole 4 - SERVICING - MAINTENANCE WARNING 4.1 - Safety measures Do not use: trichlorethylene, perchlo- Servicing or troubleshooting must be rethylene, trichloroethane or any alkaline carried out strictly in accordance with products.
  • Page 12: Bearings

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole 4.3 - Bearings The bearings are permanently greased Approximate life of the grease (depending on use) = 20,000 hours or 3 years. As an option, the bearings are regreasable Regreasing interval: 3600 hrs of operation DE bearing: Amount of grease: 60 gr...
  • Page 13: Electrical Faults

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole 4.5 - Electrical faults Fault Action Effect Check/Cause The alternator builds up and its voltage is still correct - Lack of residual magnetism when the battery is removed Connect a new battery of 4 to 12...
  • Page 14 Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole • Checking the winding Assembly A: Connect a 12 V battery in series with a rheostat of approximately You can check the winding insulation by 50 ohms - 300 W and a diode on both exciter performing a high voltage test.
  • Page 15: Dismantling, Reassembly

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole 4.6 - Dismantling, reassembly - Remove the «H» nuts for mounting the diode bridges on the support. - Change the crescents, respecting the WARNING polarity.
  • Page 16 Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole - Refit the NDE bracket on the machine - Refit the DE bracket (30) on the machine. using a dowel and nut in the shaft extension. - Slide the threaded rod into the bracket hole - Slide the threaded rod into the NDE bracket to make it easier to assemble (see basic...
  • Page 17: Installation & Maintenance Of The Pmg

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole • Reassembling the machine • Dismantling and reassembly of the filters - Mount the rotor (4) in the stator (1) (see - Remove the grille (51) then take out the drawing above) taking care not to knock the filter (52).
  • Page 18 Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole • Three-phase: 4-pole AREP excitation • Table of weights Resistances at 20 °C (Ω) (values given for information only) Stator Exciter Exciter Type...
  • Page 19: Spare Parts

    For all spare parts orders or technical sensing relays (supplied optionally). support requests, send your request to Cold resistance of cold thermistor sensors: service.epg@leroy-somer.com or your 100 to 250 Ω per sensor. nearest contact, whom you will find at www.lrsm.co/support indicating the comp- •...
  • Page 20: Exploded Views, Parts List And Tightening Torque

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole 5.4 - Exploded views, parts list and tightening torque • Single bearing...
  • Page 21 Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole • Two-bearing...
  • Page 22 Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole Screw Torque Screw Torque Ref. Qty Description Ref. Qty Description Ø Ø Stator assembly 1 Inner bearing retainer Preloading (wavy) Rotor assembly washer Exciter field (stator)
  • Page 23: Disposal And Recycling Instructions

    Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole Disposal and recycling instructions These components are usually marked with information concerning the type of plastic. committed limiting All materials listed above need special environmental impact of our activity.
  • Page 24 Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole...
  • Page 25: Ec Declaration

    Directives Nr 2006/42/EC, 2014/30/EU, 2011/65/EU and 2015/863, as well as with other relevant Directives. Moteurs Leroy-Somer undertakes to transmit, in response to a reasoned request by the national authorities, relevant information on the generator. Those responsible for compiling the technical files and this declaration are: Yannick MESSIN, Technical Manager LS Orléans, 1 rue de la Burelle, 45800 Saint Jean de Braye...
  • Page 26 Installation and maintenance Electric Power Generation 4099 en - 2022.12 / p LSA 50.2 Low Voltage Alternator - 4 pole...
  • Page 27 •Genuine spare parts •Repair services Contact us: Americas: +1 (507) 625 4011 EMEA: +33 238 609 908 Asia Pacific: +65 6250 8488 China: +86 591 8837 3010 India: +91 806 726 4867 Scan the code or go to: service.epg@leroy-somer.com www.lrsm.co/support...
  • Page 28 Connect with us at: 4099 en - 2022.12 / p...

This manual is also suitable for:

Nidec lsa 46.3

Table of Contents