Rugged cisco 5915 mobile access router combined with parvus swi-22-10 gigabit ethernet switch (39 pages)
Summary of Contents for Curtiss-Wright DuraNET 3300
Page 1
USER MANUAL DuraNET 3300 Rugged Cisco ESS-3300 L2/L3 Ethernet Switch 24x 1000BASE-T w/PoE+ and 2x 10GBASE-SR...
Page 2
Curtiss-Wright reserves the right to change the contents and form of this document, as well as the features and specifications of its products, at any time without notice.
User Manual – DuraNET 3300 Table of Contents Table of Contents Table of Contents ........................3 List of Figures ........................... 5 List of Tables ..........................6 Chapter 1 Introduction ......................7 About This Document ............................ 7 Manual Organization ..........................7 Definitions ...............................
Page 4
Minicom Client Install and Setup - Ubuntu ....................78 iperf Install and Setup – Linux Ubuntu ......................79 Automated Diagnostic Software Install and Execute .................. 80 DuraNET 3300 Port to Cisco Name Mapping ..................... 82 Glossary ..........................83 Page 4 of 84...
Chapter 3 contains connector pinouts and part numbers for all external connectors and their mating connector • Chapter 4 explains how to operate the DuraNET 3300. It describes the system connectors and cables, and includes procedures for starting the system, and usage of the zeroization capabilities. •...
Cisco IOS® software. The DuraNET 3300 serves as an ideal high bandwidth connectivity solution for size, weight, power and cost (SWaP-C)-sensitive vehicle and aircraft platforms exposed to harsh environmental and noisy conditions (e.g.
User Manual – DuraNET 3300 Introduction Features • Small form factor L2/L3 Ethernet Switch • 24x ports of Gigabit 1000BASE-T (copper) interfaces + optional 2 x ports of 10 Gigabit 10GBASE- SR (fiber optic) ports for trunking / uplinks / long hauls / EMI immunity. USB 2.0 console, RS232 console, zeroize discrete input, and optional 50ms holdup for core switch (not for PoE power) •...
461F, MIL-STD- 1275D, MIL-STD-704F, CE Mark, RTCA/DO-160 Configurations Details on DuraNET 3300 Early Access Unit (EAU) and Production configurations follow. Both EAUs and Production units share the same form factor and function, but have different power connectors and external connector coatings.
Product Number Description Starter cable set for DuraNET 3300, 24 x GbE, Mating Circular Connectors to CBL-NET-3300-01 RJ-45/USB/DB9 Starter cable set for DuraNET 3300, 24 x GbE, 2 x 10G, mating circular CBL-NET-3300-02 connectors to RJ-45/USB/DB9/Fiber-LC MNL-0676-01 Rev A4 ECO- N/A...
Chapter 2 Quick-Start Guide This section describes the physical configuration and quick-start operational testing of the DuraNET 3300. You will need two computers with at least a single USB port and single network connection. Tables 2.1 and Table 2.2 list the relationship between cables, cable port labels, and Cisco port definitions.
Cable Install and Connections Figure 2.1: Cable Diagram 1. Connect a power cable (CBL-2883-01) to port J1 on the DuraNET 3300 and the other end of the cable to the unpowered DC power source. 2. Connect network cable (CBL-2884-01) to port J2 on the DuraNET 3300 a.
RS-232 Console Port Software Terminal Emulator and Serial Console Setup Prior to communicating with the DuraNET 3300, software installation and setup must be performed to ensure proper communication. The installation instructions will be tailored for both Windows 10 and Linux operating systems for multi-user preference and experience.
User Manual – DuraNET 3300 Quick-Start Guide • Under setup option enter E and change the Bps/Par/Bits to ▪ 9600 8N1 Figure 2.4: Minicom Baud • Then save as default and exit Figure 2.5: Minicom Default • To confirm correct configuration and communication link ▪...
User Manual – DuraNET 3300 Quick-Start Guide Windows: First-time use of Windows will require installation of a USB driver, terminal emulator, console and IP address setup. • USB Driver ▪ Connection of either the USB or RS232 console cables will initiate an auto USB CP2102 driver load.
User Manual – DuraNET 3300 Quick-Start Guide The installer then asks for the Destination folder in which to install the software. Almost always it is best to use the default value. Just click Next. Figure 2.7: PuTTY Destination Then, the installer asks to select product features to install. You probably want to add a shortcut on the desktop if you expect to use the software frequently.
User Manual – DuraNET 3300 Quick-Start Guide When the installation has completed successfully, it should show a "Completed" screen. Click Finish to exit the installer. Figure 2.9: PuTTY Completed Page 20 of 84 MNL-0676-01 Rev A4 ECO- N/A Effective: 26 Feb 21...
At this point, you need to confirm the COM port connection being used for the CLI console from the DuraNET 3300. Navigate to Device Manager on your PC and select “Ports (COM & LPT) to display the COM port connection.
From the PuTTY configuration window select Serial and enter the COM port number then select Open. You should now be connected to the DuraNET 3300 Console. Figure 2.12: PuTTY Configuration with COM # Press the <Enter> key to display the DuraNET 3300 console prompt Switch> Figure 2.13: Console Prompt Page 22 of 84...
Page 23
User Manual – DuraNET 3300 Quick-Start Guide Setting static IP address Instruction for setting a static IP address can also be found here: • https://stevessmarthomeguide.com/setting-up-static-ip-address-windows-10/ To set up a static address. 1. Click on the Windows icon 2. Click the Settings icon 3.
Page 24
User Manual – DuraNET 3300 Quick-Start Guide 4. In the Network status pane locate the change adapter options link and click it Page 24 of 84 MNL-0676-01 Rev A4 ECO- N/A Effective: 26 Feb 21...
Page 25
User Manual – DuraNET 3300 Quick-Start Guide 5. You should now see your network adapters. If your PC is equipped with two, as most are, then only use one and disable the other. The Ethernet adapter is being used and the Wi-Fi adapter is disabled.
Page 26
User Manual – DuraNET 3300 Quick-Start Guide 7. Use the scroll bar to locate TCP/IPv4 and click it to highlight and then click the properties button. Page 26 of 84 MNL-0676-01 Rev A4 ECO- N/A Effective: 26 Feb 21...
Page 27
User Manual – DuraNET 3300 Quick-Start Guide If you are using DHCP then you should see a screen like the one below. You can uncheck the automatic assignment of IP address and or DNS server address. Then enter your own details as show below:...
Page 28
User Manual – DuraNET 3300 Quick-Start Guide Page 28 of 84 MNL-0676-01 Rev A4 ECO- N/A Effective: 26 Feb 21...
User Manual – DuraNET 3300 Quick-Start Guide Setting an Open Firewall Port To allow pings and data communication between the network port of this PC and the world we need to open a Firewall Port. • Open the Control Panel •...
Page 30
User Manual – DuraNET 3300 Quick-Start Guide • Windows Defender Firewall • Advanced Settings Page 30 of 84 MNL-0676-01 Rev A4 ECO- N/A Effective: 26 Feb 21...
User Manual – DuraNET 3300 Quick-Start Guide • In the left panel ▪ Inbound Rules ▪ Enable both File and Printer Sharing (ICMPv4-In) This completes opening the firewall port and you can now close all the open windows. USB Console Port Physically connect the USB cable from the J2 cable set to a USB port on the PC.
User Manual – DuraNET 3300 Quick-Start Guide Windows: • Identify the COM port assigned to the selected USB port by performing the following windows commands Start Control Panel System Device Manager Ports (COM & LPT) ▪ Silicon Labs CP210x USB to UART Bridge (COM#) •...
▪ switch> Figure 2.15: DuraNET 3300 switch> prompt Recommended Settings Each time the DuraNET 3300 is zeroized, the settings listed below are cleared. It is recommended to reenable these settings with the following commands: enable config t license smart reservation...
Connector Descriptions Chapter 3 Connector Descriptions This chapter identifies the pinouts and signal descriptions for the DuraNET 3300. It also provides connector part numbers along with suggested mating connector details as necessary. Early Access Units (EAU) and Production Units have different external connector coatings and power input connector.
Connector Pinouts This section provides the pinouts necessary for creating cables to connect to this assembly. If custom cabling is not designed and built by Curtiss-Wright, all EMI and EMC consideration must be handled by the customer. Note: EAU and Production cable pinouts are identical other than the power connector.
User Manual – DuraNET 3300 Connector Descriptions J1 Power Connector Table 3.3: J1 EAU Connector Information Recept- Recept- Wire acle # of Panel Connector Mating Cable Connector acle Gauge Used Pins Part Number Part Number Label # (AWG) Phoenix Contact 1027478...
User Manual – DuraNET 3300 Connector Descriptions Table 3.5: Phoenix Power Cables Phoenix Part Number Description 1414773 1.5 Meter Power Cable 1414791 3 Meter Power Cable 1414807 5 Meter Power Cable 1414824 10 Meter Power Cable Table 3.6: J1 Production Connector Information...
User Manual – DuraNET 3300 Connector Descriptions J2 Copper I/O Connector J2 supports GbE ports 1-8, the USB console port, the RS232 console port, and the zeroize discrete input. Table 3.8: J2 EAU Connector Information Recept- Recept- Wire # of...
Page 39
User Manual – DuraNET 3300 Connector Descriptions Signal Function Signal Function VBUS USB VBUS Sense GBE_P6.MDI3_P GBE Port 6 VBUS_GND USB VBUS Ground GBE_P6.MDI2_P GBE Port 6 No Connect GBE_P6.MDI1_P GBE Port 6 USB Ground GBE_P6.MDI0_P GBE Port 6 USB_P...
User Manual – DuraNET 3300 Connector Descriptions Signal Function Signal Function GBE_P7.MDI0_P GBE Port 7 No Connect GBE_P7.MDI0_N GBE Port 7 No Connect GBE_P5.MDI3_N GBE Port 5 GBE_P4.MDI3_P GBE Port 4 GBE_P5.MDI2_N GBE Port 5 GBE_P4.MDI2_P GBE Port 4 GBE_P5.MDI1_N GBE Port 5 GBE_P4.MDI1_P...
Page 41
User Manual – DuraNET 3300 Connector Descriptions Signal Function Signal Function GBE_P2.MDI3_P GBE Port 2 GBE_P8.MDI0_P GBE Port 8 GBE_P2.MDI3_N GBE Port 2 GBE_P8.MDI0_N GBE Port 8 GBE_P3.MDI0_P GBE Port 3 GBE_P8.MDI1_P GBE Port 8 GBE_P3.MDI0_N GBE Port 3 GBE_P8.MDI1_N GBE Port 8 GBE_P3.MDI1_P...
User Manual – DuraNET 3300 Connector Descriptions J3 Copper I/O Connector J3 supports GbE ports 9-24. Table 3.12: J3 EAU Connector Information Recept- Recept- Wire acle # of Panel Connector Mating Cable Connector acle Gauge Used Pins Part Number Part Number...
Page 43
User Manual – DuraNET 3300 Connector Descriptions Signal Function Signal Function GBE_P9.MDI2_N GBE Port 9 P14.MDI0_P GBE Port 14 GBE_P9.MDI1_N GBE Port 9 P22.MDI0_N GBE Port 22 GBE_P9.MDI1_P GBE Port 9 P22.MDI1_N GBE Port 22 GBE_P24.MDI3_P GBE Port 24 P23.MDI3_N GBE Port 23 GBE_P24.MDI3_N...
Page 44
User Manual – DuraNET 3300 Connector Descriptions Signal Function Signal Function GBE_P13.MDI1_N GBE Port 13 P21.MDI3_N GBE Port 21 GBE_P12.MDI3_P GBE Port 12 P17.MDI3_P GBE Port 17 GBE_P12.MDI2_P GBE Port 12 P17.MDI0_P GBE Port 17 GBE_P12.MDI1_P GBE Port 12 ISO_P17.MDI1_P GBE Port 17 GBE_P12.MDI0_P...
User Manual – DuraNET 3300 Connector Descriptions Table 3.15: J3 Connector Pinout – By Function Signal Function Signal Function GBE_P9.MDI0_P GBE Port 9 P17.MDI0_P GBE Port 17 GBE_P9.MDI0_N GBE Port 9 P17.MDI0_N GBE Port 17 GBE_P9.MDI1_P GBE Port 9 P17.MDI1_P GBE Port 17 GBE_P9.MDI1_N...
Page 46
User Manual – DuraNET 3300 Connector Descriptions Signal Function Signal Function GBE_P13.MDI2_P GBE Port 13 P21.MDI2_P GBE Port 21 GBE_P13.MDI2_N GBE Port 13 P21.MDI2_N GBE Port 21 GBE_P13.MDI3_P GBE Port 13 P21.MDI3_P GBE Port 21 GBE_P13.MDI3_N GBE Port 13 P21.MDI3_N GBE Port 21 GBE_P14.MDI0_P...
Configure IP Address, User Name and Password In order to configure and set parameters of the DuraNET 3300 via the Cisco WebUI, a known IP Address, Username and Password need to be assigned. Ensure a PC is connected to the DuraNET 3300 via the USB or RS232 Console and powered on.
User Manual – DuraNET 3300 Operational Description Execute the following CLI command to reboot DuraNET 3300 switch# reload Confirm reload and system reboots. After reboot enter the following CLI commands to confirm IP Address, Username and Password in the terminal window listing.
User Manual – DuraNET 3300 Operational Description Console (Linux): To confirm and verify the Cisco IOS version enter the following CLI commands switch> enable switch# sho configuration “Version 17.1”. The configuration option may show This is representative only as your system may have a different Cisco IOS.
User Manual – DuraNET 3300 Operational Description Install TFTP Server (Linux) In order to update or change the IOS of the DuraNET 3300, PC1 needs to have a TFTP server. Reference documents: “Access Router Software Upgrade Procedure”, Doc ID 49044, July 31, 2015 “Installing and Configuring TFTP Server on Ubuntu”...
User Manual – DuraNET 3300 Operational Description tftpd-hpa package should be installed (Figure 4.5:.5). Figure 4.5: tftpd-hpa package installed... Now, check whether the tftpd-hpa service is running (Figure 4.6). ~$ sudo systemctl status tftpd-hpa Figure 4.6: Check whether the tftpd-hpa service is running.
User Manual – DuraNET 3300 Operational Description Figure 4.7: tftpd-hpa is running. The default configuration file of tftpd-hpa server is /etc/default/tftpd-hpa. If you want to configure the TFTP server, then you have to modify this configuration file and restart the tftpd-hpa service.
User Manual – DuraNET 3300 Operational Description Figure 4.9: Configuration file editing. Now, we only want to change the TFTP_DIRECTORY to /tftp and add the –create option to the TFTP_OPTIONS. Without the –create option, you won’t be able to create or upload new files to the TFTP server.
User Manual – DuraNET 3300 Operational Description Now, we need to create a new directory /tftp. See Figure 4.11. ~$ sudo mkdir /tftp Figure 4.11: Create a new directory. Now, change the owner and group of the /tftp directory to tftp. See Figure 4.12 ~$ sudo chown tftp:tftp /tftp Figure 4.12: Change the owner and group.
User Manual – DuraNET 3300 Operational Description Figure 4.15: tftpd-hpa is running. Loading a new Image Select a Cisco IOS Software Image ess3x00-universalk9.17.01.01.SPA.bin Download the Cisco IOS Software Image to the TFTP Server Download the Cisco IOS software image onto your workstation or PC from the Download Software Area (Registered Customers Only).
Page 57
User Manual – DuraNET 3300 Operational Description The exclamation point "!" indicates that the copy process is in progress. When complete, confirm with the following CLI commands switch#cd flash: switch# dir “You should see the new file in the flash: directory switch# config t switch(config)#boot system flash:ess3x00-universalk9.17.01.01.SPA.bin...
User Manual – DuraNET 3300 Operational Description PoE Type1 and PoE+ Type2 Functionality and Power Check ed on any BaseT per port, not to Power over Ethernet (PoE/PoE+) support port, up to 30.0W exceed 130W total PoE power at 65°C. See Figure 4.16 below. This supports power and .
User Manual – DuraNET 3300 Operational Description Figure 4.17: minicom IP address The Username and Password can be found from the minicom window. switch>enable • • switch#sho running-config bri From PC1, open a web browser such as Firefox. Enter the DUT IP address in the URL window to bring up a Cisco GUI login:...
User Manual – DuraNET 3300 Operational Description Figure 4.18: DUT Login Window. From the GUI, navigate to Administration -> Power Management -> Total Power Supported Block Watts …enter total power requirement in the Block of 125 Watts as shown below within the oval in figure 4.18, then click...
User Manual – DuraNET 3300 Operational Description Select Yes as shown in figure 4.20. Figure 4.20: Click Yes to continue. Navigate back to dashboard to confirm setting of 125-watts as shown in POE Power Consumption pie chart (red oval). Figure 4.21: PoE power consumption box.
On the DuraNET 3300, the Zeroize Discrete is used exclusively for triggering the Zeroization / Declassification process, which zeroes and erases the switch configuration files or the entire flash file system, depending on the option provided under "service declassify".
User Manual – DuraNET 3300 Operational Description This also erases the complete NVRAM file system, therefore, all configurations, including startup and running configurations will be deleted. running-config startup-config The perma-locked bootable image(s) in the flash file system will still be available and can be used for booting the device.
Page 64
User Manual – DuraNET 3300 Operational Description switch> ping 192.0.2.1 Type escape sequence to abort. Sending 5, 100-byte ICMP Echoes to 192.0.2.1, timeout is 2 seconds: !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 1/2/4 ms 3. Copy the image via tftp switch>...
User Manual – DuraNET 3300 Specifications Chapter 5 Specifications Mechanical & Technical Specifications Dimensions Figure 5.1, Front Panel Dimensions provide the physical dimensions of the DuraNET 3300. Figure 5.1: Front Panel Dimensions Physical • Weight: 5.6 lb. (2.54 kg) for NET-3300-02H Dimensions (D x W x H), excluding connectors and mounting feet, 6.75”...
Choosing a Mounting Location – Thermal Considerations The DuraNET 3300 enclosure is highly efficient at removing heat from the inside of the unit to the outside of the finned enclosure. It is best to mount the unit on a thermally cool, thermally conductive surface to keep the overall temperature as low as possible.
User Manual – DuraNET 3300 Specifications Horizontal Mounting To install the DuraNET 3300 on its side (horizontal): 3. Create a hole pattern on the mounting surface that matches the pattern shown in Figure 5.3. The mounting holes are 0.33” in diameter.
User Manual – DuraNET 3300 Specifications Grounding • The bottom of the baseplate is conductive to allow the system grounding via the baseplate. • A blind grounding hole for attachment of a grounding cable using a #1/4-20 screw is provided on the rear of each module of the system.
User Manual – DuraNET 3300 Specifications Power • 28 VDC nominal power; input range: 9 to 36 VDC • Power consumption: <50 watts max(est), excluding PoE consumption <180W at operating temp up to 65 C° with max PoE injection •...
User Manual – DuraNET 3300 Specifications Other Specifications Reliability • Designed and manufactured using AS9100 aerospace grade / ISO 9001:2000 certified quality program • No moving parts. No fan or cold plate required • Conformal coated PCBs for humidity/tin-whisker mitigation •...
User Manual – DuraNET 3300 Troubleshooting Chapter 6 Troubleshooting Product Identification The product is labeled with the Parvus P/N and serial number. Please refer to this information when communicating with Technical Support. Technical Assistance If you have a technical question or if you cannot isolate a problem with your product, please call or e-mail...
User Manual – DuraNET 3300 Contact Info Chapter 7 Contact Info Company contact info: Curtiss-Wright Defense Solutions Division 3222 S. Washington St. Salt Lake City, Utah, USA 84115 T: +1.801.483.1533 F: +1.801.483.1523 www.curtisswrightds.com Sales: T: +1.800.483.3152 or +1.801.483.1533 slp_sales@curtisswright.com Product Technical Support: T: +1.801.433.6322...
User Manual – DuraNET 3300 Appendix A Appendix A Firefox Browser Issue and Correction Occasionally, when attempting to access the Cisco WebUI from a Firefox browser you may encounter the following access failure. To correct this: From the Firefox home page click on the symbol ≡ located in the upper right corner.
User Manual – DuraNET 3300 Appendix A Minicom Client Install and Setup - Ubuntu Ensure you have an internet connection Linux prompt: ~$ To install minicom ~$ sudo apt-get install minicom To execute minicom ~$ sudo minicom –s The –s allows for minicom setup of which the following should be confirmed...
User Manual – DuraNET 3300 Appendix A iperf Install and Setup – Linux Ubuntu Linux prompt: ~$ To install iperf ~$ sudo apt-get update ~$ sudo apt-get install iperf Executing iperf On the Server Machine (PC) o ~$ iperf –s –i5 On the Client machine (PC) o ~$ iperf –c 192.168.1.140 –i5 –t60...
User Manual – DuraNET 3300 Appendix A Automated Diagnostic Software Install and Execute Linux prompt: ~$ Install the GNU Compiler Collection (gcc) onto both PCs ~$ sudo apt install gcc Place the two test files in the following directory on the two Linux PCs Linux1: IP address 192.168.1.140...
Page 81
User Manual – DuraNET 3300 Appendix A MNL-0676-01 Rev A4 ECO- N/A Effective: 26 Feb 21 Page 81 of 84...
User Manual – DuraNET 3300 DuraNET 3300 Port to Cisco Name Mapping The Port name mappings of the DuraNET 3300 and internal Cisco hardware are listed below and can be display by executing the CLI commands • switch>enable • switch# sho int status...
User Manual – DuraNET 3300 Glossary Glossary Term Definition/Description Cisco’s operating system for their enterprise network devices (switches, routers, etc.) IOS-XE 10GBASE-SR A 10 Gigabit optical Ethernet standard. Various fiber classes allow 300-400 meter max cable length MNL-0676-01 Rev A4...
Page 84
User Manual – DuraNET 3300 Glossary {Parvus back cover, 8.5 x 11 picture inserted in front of text. DO NOT DELETE THE COMMENTS OR THIS PAGE. These comments are only visible in Normal view. The picture hides the header and these comments when you print the manual or view it in Print Layout or Print Preview.}...
Need help?
Do you have a question about the DuraNET 3300 and is the answer not in the manual?
Questions and answers