Install Vent System; Level Dryer; Connect Vent; Complete Installation - Maytag Centennial MEDC500 Install Manual

Electric dryer 29" wide models usa only
Hide thumbs Also See for Centennial MEDC500:
Table of Contents

Advertisement

Determine vent path:
Select the route that will provide straightest and most direct
path outdoors.
Plan the installation to use the fewest number of elbows and
turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed for
best drying performance:
Use following Vent system chart to determine the elbow and
hood combinations acceptable to use.
noTE: Do not use vent runs longer than those specified
in the Vent System Chart. Exhaust systems longer than those
specified will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
The Vent system chart provides venting requirements that will
help achieve best drying performance.
Vent System Chart
number
Type of vent
90° turns or
elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
Vent System Chart (long Vent models only)
number 90° turns
or elbows
0
1
2
3
4
5

Install Vent System

1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (102 mm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See "Determine vent path" in "Plan Vent System." Avoid 90º
turns. Use clamps to seal all joints. Do not use duct tape,
screws, or other fastening devices that extend into the interior
of the vent to secure vent, because they can catch lint.
Box/louvered
Angled hods
hoods
64 ft. (20 m)
58 ft. (17.7 m)
54 ft. (16.5 m)
48 ft. (14.6 m)
44 ft. (13.4 m)
38 ft. (11.6 m)
35 ft. (10.7 m)
29 ft. (8.8 m)
27 ft. (8.2 m)
21 ft. (6.4 m)
Type of vent
Box, louvered,
or angled
hoods
Rigid metal
120 ft. (36.6 m)
Rigid metal
110 ft. (33.5 m)
Rigid metal
100 ft. (30.5 m)
Rigid metal
90 ft. (27.4 m)
Rigid metal
80 ft. (24.4 m)
Rigid metal
70 ft. (21.3 m)

level Dryer

Check the levelness of the dryer. Check levelness first side to
side, then front to back.
If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again
for levelness.
noTE: It might be necessary to level the dryer again after it is
moved into its final position.

Connect Vent

1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Check that the vent is secured
to exhaust hood with a 4" (102 mm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. Once the exhaust vent connection is made, remove the
corner posts and cardboard.

Complete Installation

1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Check the dryer's final location. Be sure the vent is not
crushed or kinked.
5. Check that the dryer is level. See "Level Dryer."
6. For power supply cord installation, plug into an outlet.
For direct wire installation, turn on power.
7. Remove the protective film on the console and any tape
remaining on the dryer.
8. Wipe the dryer drum interior thoroughly with a damp cloth
to remove any dust.
9. Read "Dryer Use" in the Dryer User Instructions.
10. Set the dryer on a full heat cycle (not an air cycle) for
20 minutes and start the dryer.
If the dryer will not start, check the following:
Controls are set in a running or "On" position.
Start button has been pushed firmly.
Dryer is plugged into an outlet and/or electrical supply
is on.
Household fuse is intact and tight, or circuit breaker has
not tripped.
Dryer door is closed.