6. Be certain to keep cardboard spacer centered between doors.
Reattach outer door panel to inner door panel so handle is on
the side where hinges were just removed.
7. Attach door hinges to dryer door so that the larger hole
is at the bottom of the hinge.
8. Remove door strike (E) from cabinet. Use a small, flat-blade
screwdriver to gently remove 4 hinge hole plugs (F) on left
side of cabinet. Insert plugs into hinge holes on right side
of cabinet.
9. Insert screws into bottom holes on left side of cabinet.
Tighten screws halfway. Position door so large end of door
hinge slot is over screws. Slide door up so screws are in
bottom of slots. Tighten screws. Insert and tighten top screws
in hinges.
10. Remove door strike plug (B). Insert the door strike you
removed in Step 8 into hole and secure with screw. Insert
door strike plug into original door strike hole and secure
with screw.
11. Close door and check that door strike aligns with door catch
(C). If it is needed, slide door catch left or right within slot to
adjust alignment.
15