Champion Power Equipment 201182 Troubleshooting

Champion Power Equipment 201182 Troubleshooting

7500w wireless remote start generator

Advertisement

Quick Links

201182 - 7500W WIRELESS REMOTE START GENERATOR
TROUbLESHOOTING
Problem

Engine will not start.

Engine starts but runs roughly.

Engine will not start wirelessly.

Engine will not start electrically.

Cause
No fuel.
Faulty spark plug.
Low oil level.
Spark plug wire loose.
Fuel valve is closed.
Ignition switch OFF.
Old fuel or water in fuel.
Flooded with fuel.
CO Shield
module has been removed or
®
tampered with.
Choke lever in the wrong position.
Dirty air filter.
Dirty fuel valve.
Clogged spark arrestor.
Remote control battery is dead.
Generator battery is dead.
Battery switch is in the OFF position.
Generator out of range of remote signal.
Obstructions in between generator and
remote.
Generator battery is dead.
Battery switch is in the OFF position.
34
TROUbLESHOOTING
Solution
Add fuel.
Clean and adjust spark plug or replace.
Fill crankcase to the proper level.
Place generator on a flat, level surface.
Attach wire to spark plug.
Open fuel valve.
Press ignition switch ON.
Drain fuel and replace with fresh fuel.
Let unit stand for 10 mins.
Re-install module or contact technical support.
Move choke lever until it stops under "RUN"
position or push in completely.
Clean or replace air filter.
Clean the fuel valve.
Clean spark arrestor.
Replace remote control battery.
Recharge generator battery.
Turn battery switch to ON position.
Remote must be with 80 feet of generator.
Clear line of site between generator and remote.
Recharge generator battery.
Turn battery switch to ON position.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 201182 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Champion Power Equipment 201182

  • Page 1 TROUbLESHOOTING 201182 - 7500W WIRELESS REMOTE START GENERATOR TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Place generator on a flat, level surface.
  • Page 2 TROUbLESHOOTING 201182 - 7500W WIRELESS REMOTE START GENERATOR Problem Cause Solution Out of fuel. Fill fuel tank. Fill crankcase to the proper level. Place generator Low oil level. on a flat, level surface. Move generator to an open, outdoor area. Point exhaust away from people and buildings.
  • Page 3 TROUbLESHOOTING 201182 - 7500W WIRELESS REMOTE START GENERATOR Problem Cause Solution Starting the generator within 1 minute Wait 1 minute before trying to restart the Both CO Shield LEDs not blinking 10 ® after being manually shutoff, not a CO generator.

Table of Contents