201182 - 7500W WIRELESS REMOTE START GENERATOR
TROUbLESHOOTING
Problem
Engine will not start.
Engine starts but runs roughly.
Engine will not start wirelessly.
Engine will not start electrically.
Cause
No fuel.
Faulty spark plug.
Low oil level.
Spark plug wire loose.
Fuel valve is closed.
Ignition switch OFF.
Old fuel or water in fuel.
Flooded with fuel.
CO Shield
module has been removed or
®
tampered with.
Choke lever in the wrong position.
Dirty air filter.
Dirty fuel valve.
Clogged spark arrestor.
Remote control battery is dead.
Generator battery is dead.
Battery switch is in the OFF position.
Generator out of range of remote signal.
Obstructions in between generator and
remote.
Generator battery is dead.
Battery switch is in the OFF position.
34
TROUbLESHOOTING
Solution
Add fuel.
Clean and adjust spark plug or replace.
Fill crankcase to the proper level.
Place generator on a flat, level surface.
Attach wire to spark plug.
Open fuel valve.
Press ignition switch ON.
Drain fuel and replace with fresh fuel.
Let unit stand for 10 mins.
Re-install module or contact technical support.
Move choke lever until it stops under "RUN"
position or push in completely.
Clean or replace air filter.
Clean the fuel valve.
Clean spark arrestor.
Replace remote control battery.
Recharge generator battery.
Turn battery switch to ON position.
Remote must be with 80 feet of generator.
Clear line of site between generator and remote.
Recharge generator battery.
Turn battery switch to ON position.