SAvE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
This product meets the requirements of the PGMA (Portable Generator Manufacturers' Association) standard ANSI/PGMA G300-2018 (Safety and Performance of
Portable Generators).
Covered by one or more of the following U.S. Patent Numbers: 10,862,414 and other U.S. and foreign patents pending.
EN
3321-M-OP
REV 20211119
Champion Power Equipment, Inc., Santa Fe Springs, CA USA
Summary of Contents for Champion Power Equipment 201066
Page 1
This product meets the requirements of the PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2018 (Safety and Performance of Portable Generators). Covered by one or more of the following U.S. Patent Numbers: 10,862,414 and other U.S. and foreign patents pending. 3321-M-OP REV 20211119 Champion Power Equipment, Inc., Santa Fe Springs, CA USA...
Page 2
CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, oderless threat.
TAbLE OF CONTENTS 201066 - 6500W OPEN FRAME INvERTER TAbLE OF CONTENTS Maintenance ..........Cleaning the Generator .......... Introduction ........... Changing the Engine Oil .........
201066 - 6500W OPEN FRAME INvERTER INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines.
IMPORTANT SAFETY INSTRUCTIONS 201066 - 6500W OPEN FRAME INvERTER IMPORTANT SAFETY INSTRUCTIONS DANGER Operate equipment with guards in place. WARNING Rotating parts can entangle hands, feet, hair, clothing and/or Cancer and Reproductive Harm – www.P65Warnings.ca.gov accessories. Traumatic amputation or severe laceration can result.
Page 6
IMPORTANT SAFETY INSTRUCTIONS 201066 - 6500W OPEN FRAME INvERTER WARNING CAUTION Spark from removed spark plug wire can result in fire or Start the generator and allow the engine to stabilize before electrical shock. connecting electrical loads. Connect electrical equipment in the off position, and then turn When servicing the generator: them on for operation.
IMPORTANT SAFETY INSTRUCTIONS 201066 - 6500W OPEN FRAME INvERTER Fuel Safety When operating the generator: DO NOT move or tip the generator during operation. DANGER When transporting or servicing the generator: GASOLINE AND GASOLINE VAPORS ARE HIGHLY Always check that the fuel valve is in the OFF position and the FLAMMABLE AND EXPLOSIVE.
ACTION LABEL This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment. ETIQUETA DE ACCIÓN ÉTIQUETTE D'ACTION...
IMPORTANT SAFETY INSTRUCTIONS 201066 - 6500W OPEN FRAME INvERTER Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
IMPORTANT SAFETY INSTRUCTIONS 201066 - 6500W OPEN FRAME INvERTER Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
2mm safe margin; to be printed on white substrate doors and intake ventilation covers. This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
CONTROLS AND FEATURES 201066 - 6500W OPEN FRAME INvERTER CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1. Gasoline Gauge 8.
CONTROLS AND FEATURES 201066 - 6500W OPEN FRAME INvERTER Control Panel 1. Ignition Switch – Used to START or STOP the generator. RECEPTACLES 2. Choke – Used to start a cold engine. 120V AC, 30A RV (NEMA TT-30R) 3. Intelligauge with Power Meter – Four mode digital meter...
CONTROLS AND FEATURES 201066 - 6500W OPEN FRAME INvERTER Intelligauge with Power Meter and CO Shield ® The meter is divided into two separate displays. The LCD displays each mode for several seconds and then automatically cycles through. The Power Meter LED displays output in percent (%) with 100% at the top.
CONTROLS AND FEATURES 201066 - 6500W OPEN FRAME INvERTER FCC Statement Parts Included 1. This device complies with Part 15 of the FCC Rules. Operation Accessories is subject to the following two conditions: Engine Oil ........37.2 fl. oz. (1100 ml) 1a.
ASSEMbLY 201066 - 6500W OPEN FRAME INvERTER ASSEMbLY Install the Wheel Kit Your generator requires some assembly. This unit ships from our CAUTION factory without oil. It must be properly serviced with fuel and oil before operation. The wheel kit is not intended for over-the-road use.
ASSEMbLY 201066 - 6500W OPEN FRAME INvERTER 4. Place an r-clip (J) on the end of the short pin and fasten 1. Place the generator on a flat, level surface. securely. 2. Remove oil fill cap/dipstick to add oil. 3. Using a funnel, add up to 37.2 fl. oz. (1100 ml) of oil (included) and replace oil fill cap/dipstick.
ASSEMbLY 201066 - 6500W OPEN FRAME INvERTER NOTICE The first 5 hours of run time are the break-in period for the unit. During the break in period stay at or below 50% of the running watt rating and vary the load occasionally to allow stator windings to heat and cool.
2mm safe margin; to be printed on white substrate This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
Page 20
OPERATION 201066 - 6500W OPEN FRAME INvERTER In the event of an engine shut off, when you approach the NOTICE generator to investigate, a blinking red LED light in the CO Shield ® area provides notification that the generator shut off due to an...
OPERATION 201066 - 6500W OPEN FRAME INvERTER Generator Location WARNING WARNING Do not expose to rain or use in damp locations. Keep all objects a minimum of 5 feet (1.5m) away from the NEVER operate the generator inside any building, garage, generator at all times.
OPERATION 201066 - 6500W OPEN FRAME INvERTER 4. Turn the engine switch to the “ON” position. NOTICE For gasoline restarts with hot engine in hot ambient temperature >86°F (30°C): Move the choke to the “CHOKE” position for only one start attempt. If generator does not start after first attempt, move the choke to the “RUN”...
OPERATION 201066 - 6500W OPEN FRAME INvERTER WARNING Always remember to plug your appliances directly into the generator and do not plug the generator power cord into any electrical outlet or connect to the circuit breaker panel in your home.
OPERATION 201066 - 6500W OPEN FRAME INvERTER 2. Press the “TEST” (C) button located on the front of the receptacle to trip the device. This should immediately stop the flow of electricity and shut off the lamp. If the electricity is not stopped, do not use this receptacle until it has been serviced or replaced.
Storage section for proper engine and fuel storage. The Champion model 201066 is parallel ready and can be operated in parallel with another Champion unit to increase the total available electrical power. A Champion parallel kit (optional Moving the Generator equipment) is required for parallel operation.
MAINTENANCE 201066 - 6500W OPEN FRAME INvERTER MAINTENANCE Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, dirt, moisture or corrosive vapors.
MAINTENANCE 201066 - 6500W OPEN FRAME INvERTER 2. Use pliers to slide the spring clamp down the oil drain hose and pull the hose off the plug bracket. DRAIN PLUG DRAIN TUBE 3. Inspect the electrode on the plug. It must be clean and not 3.
MAINTENANCE 201066 - 6500W OPEN FRAME INvERTER Cleaning the Spark Arrestor Maintenance Schedule 1. Allow the engine to cool completely before servicing the spark Follow the service intervals indicated in the following maintenance arrestor. schedule. 2. Remove the two screws holding the cover plate which retains Service your generator more frequently when operating in adverse the spark arrestor to the muffler.
STORAGE 201066 - 6500W OPEN FRAME INvERTER STORAGE WARNING To avoid accidental or unintended ignition of your generator during periods of storage, the following precautions should be followed: – When storing the generator make sure the engine switch and fuel valve are set to the “OFF” position.
STORAGE 201066 - 6500W OPEN FRAME INvERTER Removing from Storage NOTICE If the generator has been improperly stored for a period longer than 30 days with ethanol blended gasoline in the gasoline tank and/or carburetor, all fuel must be drained and the carburetor must be thoroughly cleaned of ethanol build up.
SPECIFICATIONS 201066 - 6500W OPEN FRAME INvERTER SPECIFICATIONS Oil Specifications DO NOT OVERFILL. Generator Specifications Type ..........*See following chart Generator Model ......... ..
TROUbLESHOOTING 201066 - 6500W OPEN FRAME INvERTER TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Place generator on a flat, level surface.
Page 33
TROUbLESHOOTING 201066 - 6500W OPEN FRAME INvERTER Problem Cause Solution Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak. Make sure there are no objects creating obstructions within 5 feet of the generator.
Page 34
TROUbLESHOOTING 201066 - 6500W OPEN FRAME INvERTER Problem Cause Solution Engine governor defective. Contact the help line. Dirty fuel valve. Clean the fuel valve. Engine hunts or falters. Carburetor is dirty and running lean. Contact the help line. Move choke until it stops under RUN position or Choke in wrong position.
(parts and labor) from Champion Power Equipment disclaims any obligation to cover the original date of purchase and 270 days (parts and labor) for any loss of time, use of this product, freight, or any incidental commercial and industrial use.
Page 36
THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) emissions regulations.
Page 37
EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (SORE) (for other states, 1997 and later model year engines). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
Page 38
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.
Need help?
Do you have a question about the 201066 and is the answer not in the manual?
Questions and answers
Howdy Access the AVR on a 201066