Zimmer GEP2000IO-45 Installation And Operating Instructions Manual

Zimmer GEP2000IO-45 Installation And Operating Instructions Manual

2-jaw parallel grippers electric
Table of Contents

Advertisement

Quick Links

INSTALLATION AND
OPERATING
INSTRUCTIONS
2-jaw parallel grippers electric
GEP2000IO-00
GEP2000IO-05
GEP2000IO-45
GEP2000IL-00
DDOC01113
THE KNOW-HOW FACTORY
www.zimmer-group.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GEP2000IO-45 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zimmer GEP2000IO-45

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS 2-jaw parallel grippers electric GEP2000IO-00 GEP2000IO-05 GEP2000IO-45 GEP2000IL-00 DDOC01113 THE KNOW-HOW FACTORY www.zimmer-group.com...
  • Page 2 Depending on the application, this can be the end position or the work position.  Workpiece loss Function which, in case of workpiece loss, causes the product to move to the end position. detection Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 3: Table Of Contents

    12.4.4 PositionTolerance ........................................26 12.4.5 GripForce ..........................................27 12.4.6 TeachPosition ........................................27 12.4.7 StatusWord ...........................................28 12.4.8 Diagnosis ..........................................29 12.4.9 ActualPosition ........................................29 12.5 Cold start ............................................30 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 4 19 RoHS declaration ..................................44 20 REACH declaration ..................................44 21 Declaration of Incorporation ..............................45 22 Declaration of Conformity ................................. 46 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 5: Supporting Documents

    This category contains useful tips for handling the product efficiently. Failure to observe these tips will not result in damage to the product. This information does not include any information relevant to health or workplace safety. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 6: Safety Notices

    ► Observe the specified maintenance intervals and specifications regarding the quality of the operating material. ► When using the product under extreme conditions, adjust the maintenance interval according to the degree of contamination. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 7: Proper Use

    Installation, commissioning and maintenance may only be performed by trained specialists. These persons must have read and understood the installation and operating instructions in full. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 8: Product Description

    A type plate is attached to the housing of the product. The article number and confirmation number are shown on the type XX-XXXXXX plate. Article number Confirmation number Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 9: Functional Description

    Despite its small installation space, the product is suited for gripping a wide range of form-fit and frictional fit parts. The product can be controlled like a valve via I/O ports or via IO-Link. Power supply Emergency release Gripper jaw Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 10: Led Status Display

    (e.g. an emergency stop). ► Please contact Zimmer Customer Service if you have any questions. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 11: Technical Data

    8 Accessories/scope of delivery INFORMATION If any accessories not sold or authorized by Zimmer GmbH are used, the function of the product cannot be guaranteed. Zimmer GmbH accessories are specifically tailored to the individual products. ► For optional accessories and those included in the scope of delivery, refer to our website.
  • Page 12: Installation

    ► Observe the tightening torque of the mounting screws. ► Verify the permitted load capacity of the required screw connections in accordance with VDI 2230. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 13: Installing The Product

    ► Use an adapter plate if necessary. ► For information on optional accessories and those included in the scope of delivery, refer to our website. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 14: Safe Shutoff For Products With Io-Link

    (GND). Because of the self-locking mechanism, the product remains in the last approached position, even if no voltage is supplied. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 15: Installing The Energy Supply

    10.3 Installing the energy supply NOTICE The cables that are used by Zimmer GmbH feature a minimum bending radius of 10 x the outer diameter. This bending radius must not be undershot! ► Freely suspended cables must be secured to prevent excessive motion loads or pinching.
  • Page 16: Pin Assignment Gep2000Io-00

    GND actuator 0 V DC actuator supply voltage ► Connect the product to the IO-Link master. ► Ensure the proper voltage supply. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 17: Static Charge

    ► Before installing an accessory, make sure it is suitable for use with the selected variant. ► You can find information on our website. ► Please contact Zimmer Customer Service if you have any questions. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 18: Commissioning For Gep2000Io-00/Gep2000Io-05/Gep2000Io-45

    The current jaw position is scaled from 0 V to 10 V and is issued via PIN 5 (analog output). > 10 ms 24 V PIN 2  > 10 ms 24 V PIN 4  Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 19: Current Supply Profile Of Gripping Process

    > 5 ms 24 V PIN 4  11.4 Minimum travel path Design size Minimum travel path per gripper jaw [mm] GEP20XXIO-00 GEP20XXIO-05 GEP20XXIO-45 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 20: Commissioning The Gep2000Il-00

    UINT8 TeachPosition UINT16 GripForce UINT8 PositionTolerance UINT8 Input Control system Gripper Output Name Data type StatusWord UINT16 Diagnosis UINT16 ActualPosition UINT16 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 21: Iodd Import

    Ö The data transmission is complete when the product sends back Statusbit 12 = DataTransferOK = FALSE.  INFORMATION ► For examples, refer to the "Quickstart Basic Parameters" section. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 22: Parameters

    Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 2 Adjust Teach ResetDirec- WritePDU DataTransfer tionFlag Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 23 This bit can be used to acknowledge all errors that can be reset. Whether an error can be reset is shown in the "Error Diagnosis" section. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 24: Devicemode

    Inside and outside gripping, both movements at the same speed. Name DeviceMode Data format UINT8 Permission Write Transfer Cyclical Value range 60, 63, 70, 73, 100, 103 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 25 500 ms after a gripped workpiece mand NOTICE In case of workpiece loss, the product moves to the end position and outputs a message. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 26: Workpieceno

    This means that the TeachPosition range starts at 13.50 mm and goes all the way up to 16.50 mm. Name PositionTolerance Data format UINT8 Permission Write Transfer Cyclical Value range 0 ... 255 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 27: Gripforce

    0 to max. 3200  Name TeachPosition Data format UINT16 Permission Write Transfer Cyclical Value range 0 to max. jaw stroke of the product Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 28: Statusword

    Active if the product has an active error. The error message can be determined using Diagnosis. Name StatusWord Data format UINT16 Permission Read Transfer Cyclical Value range 0 ... 65535 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 29: Diagnosis

    ► During commissioning, be aware of fluctuations around the exact value if you use the ActualPosition parameter to detect the workpiece. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 30: Cold Start

    ► Transmit the parameters to the product with a handshake. INFORMATION ► For more information please refer to the „Handshake Data Transfer Method“ section. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 31: Quickstart Basic Parameters

    // Product moves to WorkPosition (0x0200 or 512(decimal) = MoveToWork) iStep := 100; END_IF 100: // Continue with the program END_CASE Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 32: Starting The Gripping Movement

    // ControlWord 0x0200 = FALSE in ControlWord) ControlWord := 512; // Moves back toward WorkPosition iStep := 100; END_IF; 100: // Continue with the program END_CASE Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 33: Recipe Examples

    // Query for completion of the data transfer, // DataTransferOK = FALSE iStep := 0; // Storage is completed END_IF; END_CASE Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 34: Loading A Recipe

    := 0; //Handshake is completed, // Parameters from the third recipe have been taken over into the current process parameters. END_IF; END_CASE Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 35: Operation

    ► Please contact Zimmer Customer Service if you have any questions. 13.1 Setting the gripping force GEP2000IO The gripping force can be adjusted in four stages using a rotary switch. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 36: Emergency Release Of Gep2000Io

    ► Actuate the emergency release with a corresponding Allen key. Design size Wrench size [mm] GEP2006IO-XX  GEP2010IO-XX GEP2013IO-XX GEP2016IO-XX Protective cap Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 37: Setting The Gripping Force Gep2000Il-00

    14 Gripping force charts INFORMATION ► You can find information on our website. ► Please contact Zimmer Customer Service if you have any questions. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 38: Error Diagnosis

    Customer Service. 0x0306 DeviceMode is not plausible. • Transmitted DeviceMode is ► Check the transmitted not plausible. process data. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 39 ► Please contact Zimmer Customer Service. 0x0411 No production parameters • Internal error ► Please contact Zimmer present on the product. Customer Service. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 40: Status In Led Display For Error Gep2000Io

    ⬤ ⬤ ⬤ Red LED flashes every second. • A reference run is being performed. Green LED flashes every second (alternating). Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 41 0x0109 ShiftPosition UINT16 Read 0 to max. Reflection of the process data (265) jaw stroke of the product Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 42 • Value = 0 ► Activation of message 0x0400 by ISDU: • Index = 562 (decimal) • Subindex = 0 • Value = 1 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 43: Maintenance

    ► Dispose of the components properly according to the material groups. ► Comply with the locally applicable environmental and disposal regulations. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 44: Rohs Declaration

    Authorized representative for the (Place and date of issuance) Martin Zimmer compilation of relevant technical (Legally binding signature) documents Managing Partner Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 45: Declaration Of Incorporation

    Authorized representative for the (Place and date of issuance) Martin Zimmer compilation of relevant technical (Legally binding signature) documents Managing Partner Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 46: Declaration Of Conformity

    Authorized representative for the (Place and date of issuance) Martin Zimmer compilation of relevant technical (Legally binding signature) documents Managing Partner Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 47 INSTALLATION AND OPERATING INSTRUCTIONS 2-jaw parallel gripper electric, robot-specific GEP2006IO-12-B-01 GEP2010IO-12-B-01 GEP2013IO-12-B-01 GEP2016IO-12-B-01 DDOC01113-01  THE KNOW-HOW FACTORY www.zimmer-group.com...
  • Page 48 Depending on the application, this can be the end position or the work position.  Workpiece loss Function which, in case of workpiece loss, causes the product to move to the end position. detection Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 49 Product description ................................7 Functional description ................................7 Installing the product  ................................7 Installing the energy supply ......................................7 Installing the wiring  ........................................8 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 50: Supporting Documents

    This category contains useful tips for handling the product efficiently. Failure to observe these tips will not result in damage to the product. This information does not include any information relevant to health or workplace safety. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 51: Safety Notices

    ► Observe the specified maintenance intervals and specifications regarding the quality of the operating material. ► When using the product under extreme conditions, adjust the maintenance interval according to the degree of contamination. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 52: Proper Use

    Installation, commissioning and maintenance may only be performed by trained specialists. These persons must have read and understood the installation and operating instructions in full. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 53: Product Description

    7.1 Installing the energy supply NOTICE The cables that are used by Zimmer GmbH feature a minimum bending radius of 10 x the outer diameter. This bending radius must not be undershot! ► Freely suspended cables must be secured to prevent excessive motion loads or pinching.
  • Page 54: Installing The Wiring

    Ö A voltage supply between PIN 5 and PIN 8 is necessary for operation. Ö A jaw movement is triggered by a voltage level between PIN 7 or PIN 6. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 55 ► Observe a break time of 10 ms between the reset of the signal and the next command. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...

This manual is also suitable for:

Gep2000io-05Gep2000io-00Gep2000il-00

Table of Contents