If you want this option to be activated again you will need to press the M button for 3 seconds.
6. Window detector function
Press
to enter window detecor function. Then press "
selected, the window detection function is activated and
temperature drop is detected, the appliance will automatically enter anti-freeze mode with
If temperature rises up, the appliance will go back to previous mode with
to disable the window detection function.
Remarks: the window detector function is not available under anti-freeze mode.
7. In case of power failure
All of the above settings for temperature, time, date of the week, and programs remain valid until the power is
removed.
After a power failure, when power is restored, the device will go back to the mode and temperature
selected before the power failure.
In the event of a power failure, the device only saves the following parameters: temperature and operating
mode. When the power is restored, the date and time must be set in order to make the various programs work
correctly.
TECHNICAL SPECIFICATIONS
Model
Voltage
Frequency
Rated power
Protection
class
IP Protection
Pilot wire
Information requirements for electric local space heaters
Model identifier(s): HT10PXD/ASPEN-10S
Item
Heat output
Nominal heat output P
HT10PXD/ASPEN-10S
230 V ~
50 Hz
1000 W
II
IPX4
6 orders
Symbol
Value
1
nom
/
HT15PXD/ASPEN-15S
230 V ~
50 Hz
1500 W
II
IPX4
6 orders
Unit
Type of heat input, for electric storage local space
heaters only (select one)
kW
manual heat charge control, with
13
" to choose "ON" or "OFF". If "ON" is
icon will show on the screen. When
icon on. You can choose "OFF"
HT20PXD/ASPEN-20S
230 V ~
50 Hz
2000W
II
IPX4
6 orders
Item
icon flashing.
Unit
No